Evidence map›Paper›PMID 31686922›Full record

ArticleMedical devices (Auckland, N.Z.)2019

Comparison of blood pressure measurements in the upper and lower extremities versus arterial blood pressure readings in children under general anesthesia.

Seth Hayes, Rebecca Miller, Ambrish Patel, Dmitry Tumin, Hina Walia, Mohammed Hakim, Faizaan Syed, Joseph D Tobias

Open access · goldAbstract read
In one paragraph

Article in Medical devices (Auckland, N.Z.), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Observational
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Seth HayesDepartment of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH 43205, USA.
Rebecca MillerDepartment of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH 43205, USA.
Ambrish PatelDepartment of Pediatrics, The Ohio State University, Columbus, OH 43210, USA.
Dmitry TuminDepartment of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH 43205, USA.
Hina WaliaDepartment of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH 43205, USA.
Mohammed HakimDepartment of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH 43205, USA.
Faizaan SyedDepartment of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH 43205, USA.
Joseph D TobiasDepartment of Anesthesiology and Pain Medicine, Nationwide Children's Hospital, Columbus, OH 43205, USA.
Nationwide Children's Hospital · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare invasive blood pressure (IBP) readings obtained from an arterial cannula with non-invasive blood pressure (NIBP) measurements from oscillometric cuffs on the upper and lower extremities of infants and children under general anesthesia. PATIENTS AND

methodsPatients under 10 years of age were enrolled in our study if they were to receive general anesthesia with planned placement of a radial arterial cannula. At 5 mins intervals, IBP was measured using a fluid-coupled pressure transducer and NIBP was measured with two oscillometers with appropriately sized cuffs placed on the upper arm and lower leg, for 10 readings per patient.

resultsThe study enrolled 18 boys and 12 girls, ranging in age from 0 to 8 years. Across 300 data points, the absolute difference between the arm and invasive mean arterial pressure (MAP) measurements was 7±7 mmHg (range: 0-52 mmHg). The absolute difference between the leg and invasive MAP measurements was 8±8 mmHg (range: 0-52 mmHg). Although both non-invasive measurement sites demonstrated frequent deviation from invasive measurement, large deviations were more common when BP was measured at the leg (81 of 298 observations (27%) deviating by >10 mmHg) compared to the arm (60 of 300 observations (20%) deviating by >10 mmHg).

conclusionThe frequency of clinically significant NIBP deviation in children under general anesthesia supports the importance of IBP monitoring when hemodynamic fluctuations are likely and would be particularly detrimental. NIBP measured at the lower leg is more likely to result in clinically significant deviation from invasively measured MAP than NIBP values obtained from an upper arm.

Indexed as

blood pressure cuffinvasive blood pressurenon-invasive blood pressure

Identifiers

PMID31686922
PMCPMC6709812
OpenAlexW2969690542

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.