Evidence map›Paper›PMID 31686396›Full record

ArticleBiological trace element research2020

Metals and Metalloids Release from Orthodontic Elastomeric and Stainless Steel Ligatures: In Vitro Risk Assessment of Human Exposure.

Aneta Olszewska, Anetta Hanć, Danuta Barałkiewicz, Piotr Rzymski

Abstract read
In one paragraph

Article in Biological trace element research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Aneta OlszewskaDepartment of Facial Malformation, Poznan University of Medical Sciences, Poznań, Poland.
Anetta HanćDepartment of Trace Element Analysis by Spectrometry Method, Faculty of Chemistry, Adam Mickiewicz University, Poznań, Poland.
Danuta BarałkiewiczDepartment of Trace Element Analysis by Spectrometry Method, Faculty of Chemistry, Adam Mickiewicz University, Poznań, Poland.
Piotr RzymskiDepartment of Environmental Medicine, Poznan University of Medical Sciences, Poznań, Poland. rzymskipiotr@ump.edu.pl.ORCID http://orcid.org/0000-0002-4713-0801

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Elastomeric ligatures are increasingly used as a part of esthetic orthodontic treatment, particularly in children. The aim of the present study was to experimentally test whether these appliances may contribute to exposure to toxic elements. In the present study, elastomeric ligatures (ELs) were incubated in artificial human saliva for 1 month (a typical period of their use) and the release of 21 metals (Ba, Cd, Co, Cr, Cu, Fe, Li, Mn, Mg, Mo, Ni, Pb, Rb, Tl, Ti, Sb, Sr, Sn, Zn, U, V) and 2 metalloids (As and Ge) was studied using inductively coupled plasma-mass spectrometry. For comparison, stainless steel ligatures (SLs) were incubated for 1, 3, and 6 months (since sometimes their use is prolonged) under similar conditions. The determined metal levels were compared to the corresponding safety limits for human exposure. During 1 month, the ELs released Cd, Co, Cr, Mn, Ni, and Sn at total mean ± SD level of 0.31 ± 0.09, 0.98 ± 0.30, 3.96 ± 1.31, 14.7 ± 8.5, 13.8 ± 4.8, and 49.5 ± 27.7 μg, respectively. Other elements were always below the detection limits. In case of SL, the release of Co, Cr, Fe, Ni, Mn, and Sn was observed, and the determined values increased over the studied period. After 6 months, their total mean ± SD levels amounted to 28.6 ± 0.2, 21.7 ± 0.2, 623.5 ± 3.0, 1152.7 ± 1.8, 5.5 ± 0.3, and 22.6 ± 0.2 μg, respectively. The released metal levels from both ligature types were always below safety limits. The release of Ni from SL during 6 months would constitute 5.0 and 11.5% of tolerable intake in adults and children, respectively. The results of this in vitro study highlight that the use of ligatures in orthodontic treatment can be considered safe in terms of metal exposure although elastic ligatures replaced on a monthly basis appear to be advantageous in comparison to the prolonged use of stainless steel appliances.

Indexed as

LigationElastomersHumansMetalloidsMetals, HeavyOrthodontic AppliancesRisk AssessmentStainless SteelElastomersMetalloidsMetals, HeavyStainless SteelArtificial salivaElastomeric ligaturesMetal exposureNickelOral cavityOrthodontic appliances

Identifiers

PMID31686396
PMCPMC7306017

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.