Evidence map›Paper›PMID 31684973›Full record

ArticleHead & face medicine2019

Effect of mandibular position achieved using an oral appliance on genioglossus activity in healthy adults during sleep.

Michikazu Matsuda, Toru Ogawa, Ratri M Sitalaksmi, Makiko Miyashita, Toshimi Ito, Keiichi Sasaki

Open access · goldAbstract read
In one paragraph

Article in Head & face medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Michikazu MatsudaDivision of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan.
Toru OgawaDivision of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan. ogat-thk@umin.ac.jp.
Ratri M SitalaksmiDivision of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan.
Makiko MiyashitaDivision of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan.
Toshimi ItoDivision of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan.
Keiichi SasakiDivision of Advanced Prosthetic Dentistry, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi, 980-8575, Japan.
Tohoku University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOral appliances (OAs) are generally designed to displace the mandible anteriorly and downward, to increase the airway patency. The present study aimed to examine the relationship between genioglossus (GG) muscle activity and mandibular position, considering both anterior and vertical displacements during sleep.

methodsSeven healthy male adults aged 29.4 ± 1.99 years were evaluated. Maxillary and mandibular OAs were fabricated from 2-mm-thick resin plates with pressure-welding. The activity of the left GG was recorded using two silver ball electrodes attached to the lingual edge of the mandibular OA. Respiratory status and right masseter muscle activity were measured by an airflow sensor and surface electrodes, respectively. Electroencephalography was used to determine the sleep status. Stage 2 (the second stage of sleep) was defined as the state of sleeping. Four test conditions with different mandibular positions (0 and 50% anterior protrusion) and bite openings (4 mm and 12 mm) were examined.

resultsGG activity in SL4A (4 mm bite opening, 50% protrusion during sleep) and SL12 (12 mm bite opening, 0% protrusion during sleep) were significantly higher than that in SL4 (4 mm bite opening, 0% protrusion during sleep). Respiratory volume did not significantly differ between all test conditions.

conclusionGG activity is influenced not only by anterior protrusion of the mandible but also by vertical displacement during sleep. Thus, when determining the effectiveness of intraoral appliances in the treatment of obstructive sleep apnea, both protrusion and the size of the mandibular opening should be evaluated and taken into account.

Indexed as

MandibleMandibular AdvancementSleep Apnea, ObstructiveAdultDental OcclusionFacial MusclesHumansMaleProstheses and ImplantsTongueMandibular positionObstructive sleep apneaOral applianceSleep

Identifiers

PMID31684973
PMCPMC6827235
OpenAlexW2986292448

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.