Evidence map›Paper›PMID 31679093›Full record

ArticleBiomechanics and modeling in mechanobiology2020

Computational study on the haemodynamic and mechanical performance of electrospun polyurethane dialysis grafts.

Sjeng Quicken, Yeshi de Bruin, Barend Mees, Jan Tordoir, Tammo Delhaas, Wouter Huberts

Open access · hybridAbstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 14 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. The impact of shape uncertainty on aortic-valve pressure-drop computations.International journal for numerical methods in biomedical engineering · 2021
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Sjeng QuickenDepartment of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 50, 6223ER, Maastricht, The Netherlands.ORCID http://orcid.org/0000-0002-4496-3998
Yeshi de BruinDepartment of Biomedical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB, Eindhoven, The Netherlands.
Barend MeesDepartment of Vascular Surgery, Maastricht University Medical Centre, PO Box 5800, 6229 HX, Maastricht, The Netherlands.
Jan TordoirDepartment of Vascular Surgery, Maastricht University Medical Centre, PO Box 5800, 6229 HX, Maastricht, The Netherlands.
Tammo DelhaasDepartment of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 50, 6223ER, Maastricht, The Netherlands.
Wouter HubertsDepartment of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 50, 6223ER, Maastricht, The Netherlands. wouter.huberts@maastrichtuniversity.nl.
Maastricht University · NLMaastricht University Medical Centre · NLEindhoven University of Technology · NL

Funding

Chemelote InSciTe BM1.01
6 · The paper itself

Abstract

Compliance mismatch between an arteriovenous dialysis graft (AVG) and the connected vein is believed to result in disturbed haemodynamics around the graft-vein anastomosis and increased mechanical loading of the vein. Both phenomena are associated with neointimal hyperplasia development, which is the main reason for AVG patency loss. In this study, we use a patient-specific fluid structure interaction AVG model to assess whether AVG haemodynamics and mechanical loading can be optimised by using novel electrospun polyurethane (ePU) grafts, since their compliance can be better tuned to match that of the native veins, compared to gold standard, expanded polytetrafluoroethylene (ePTFE) grafts. It was observed that the magnitude of flow disturbances in the vein and the size of anastomotic areas exposed to highly oscillatory shear ([Formula: see text]) and very high wall shear stress ([Formula: see text]) were largest for the ePTFE graft. Median strain and von Mises stress in the vein were similar for both graft types, whereas highest stress and strain were observed in the anastomosis of the ePU graft. Since haemodynamics were most favourable for the ePU graft simulation, AVG longevity might be improved by the use of ePU grafts.

Indexed as

Computer SimulationRenal DialysisBiomechanical PhenomenaBlood Flow VelocityHemodynamicsHumansPolyurethanesPressureStress, MechanicalPolyurethanesDialysis graftFluid structure interaction modellingMaterial choicePolyurethane

Identifiers

PMID31679093
PMCPMC7105427
OpenAlexW2987818685

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.