Evidence map›Paper›PMID 31677640›Full record

ArticleWorld journal of surgical oncology2019

Skin sparing mastectomy and robotic latissimus dorsi-flap reconstruction through a single incision.

Gilles Houvenaeghel, Marie Bannier, Sandrine Rua, Julien Barrou, Mellie Heinemann, Eric Lambaudie, Monique Cohen

Open access · goldAbstract read
In one paragraph

Article in World journal of surgical oncology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Gilles HouvenaeghelDepartment of Surgical Oncology, Paoli Calmettes Institute and CRCM, CNRS, INSERM, Aix Marseille Université, 232 Bd de Sainte Marguerite, 13009, Marseille, France. houvenaeghelg@ipc.unicancer.fr.ORCID http://orcid.org/0000-0002-4384-6255
Marie BannierDepartment of Surgical Oncology, Paoli Calmettes Institute, Marseille, France.
Sandrine RuaDepartment of Surgical Oncology, Paoli Calmettes Institute, Marseille, France.
Julien BarrouDepartment of Surgical Oncology, Paoli Calmettes Institute, Marseille, France.
Mellie HeinemannDepartment of Surgical Oncology, Paoli Calmettes Institute and CRCM, CNRS, INSERM, Aix Marseille Université, 232 Bd de Sainte Marguerite, 13009, Marseille, France.
Eric LambaudieDepartment of Surgical Oncology, Paoli Calmettes Institute and CRCM, CNRS, INSERM, Aix Marseille Université, 232 Bd de Sainte Marguerite, 13009, Marseille, France.
Monique CohenDepartment of Surgical Oncology, Paoli Calmettes Institute, Marseille, France.
Institut Paoli-Calmettes · FRCentre National de la Recherche Scientifique · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRobotic latissimus dorsi-flap reconstruction (RLDFR) after skin-sparing mastectomy (SSM) for breast cancer (BC) has been performed through a single nipple incision. We report results of SSM with RLDFR, mainly with analysis of feasibility, morbidity, indications, and technique standardization.

methodsWe determined characteristics of patients, previous treatment of BC, and type of reconstruction. Surgical technique, duration of surgery, and complication rate were reported according to three successive periods: P1-3.

resultsForty RLDFR, with breast implant for 16 patients, with previous breast radiotherapy in 30% had been performed. In logistic regression, factors significantly associated with duration of surgery ≥ 300 min were P2 (OR 0.024, p = 0.004) and P3 (OR 0.012, p = 0.004) versus P1. The median mastectomy weight was 330 g and 460 g for BMI < and ≥ 23.5 (p = 0.025). Length of hospitalization was 4 days. Total complication rate was 20% (8/40): seven breast complications (four re-operations) and one RLDF complication with re-operation. Periods were significantly predictive of complications (p = 0.045).

conclusionSSM with RLDFR is feasible, safe, and reproducible. We reported a decrease of duration of surgery, length of post-operative hospitalization, and complication rate.

Indexed as

Surgical FlapsAdultAgedAged, 80 and overFemaleHumansMammaplastyMastectomyMiddle AgedPostoperative ComplicationsProspective StudiesRobotic Surgical ProceduresBreast reconstructionLatissimus dorsi-flapRobotic surgery

Identifiers

PMID31677640
PMCPMC6825710
OpenAlexW2983424338

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.