ReviewTissue engineering. Part B, Reviews2020
Small Diameter Xenogeneic Extracellular Matrix Scaffolds for Vascular Applications.
Review in Tissue engineering. Part B, Reviews, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- Using Low-Speed Rotation in Heparin Immobilization Improved Antithrombogenicity of Tubular Acellular Vascular Scaffolds.Tissue engineering and regenerative medicine · 2026Article
- Human acellular amniotic membrane/polycaprolactone vascular grafts prepared by electrospinning enable vascular remodeling in vivo.Biomedical engineering online · 2024Article
- Fabrication of a Triple-Layer Bionic Vascular Scaffold via Hybrid Electrospinning.Journal of functional biomaterials · 2024Article
- Heparin coated decellularized xenogeneic small diameter vascular conduit for vascular repair with early luminal reendothelialization.Cell and tissue banking · 2023Article
- In vivo efficacy of a polymer layered decellularized matrix composite as a cell honing cardiovascular tissue substitute.Materials today. Bio · 2022Article
- A critical review of fibrous polyurethane-based vascular tissue engineering scaffolds.Journal of biological engineering · 2022Review
- Basement Membrane of Tissue Engineered Extracellular Matrix Scaffolds Modulates Rapid Human Endothelial Cell Recellularization and Promote Quiescent Behavior After Monolayer Formation.Frontiers in bioengineering and biotechnology · 2022Article
- Photooxidation and Pentagalloyl Glucose Cross-Linking Improves the Performance of Decellularized Small-Diameter Vascular XenograftFrontiers in bioengineering and biotechnology · 2022Article
- Tissue engineered bovine saphenous vein extracellular matrix scaffolds produced via antigen removal achieve high in vivo patency rates.Acta biomaterialia · 2021Article
- Selection of different endothelialization modes and different seed cells for tissue-engineered vascular graft.Bioactive materials · 2021Review
- Ex Vivo and In Vivo Analysis of a Novel Porcine Aortic Patch for Vascular Reconstruction.International journal of molecular sciences · 2021Article
- A novel polymeric fibrous microstructured biodegradable small-caliber tubular scaffold for cardiovascular tissue engineering.Journal of materials science. Materials in medicine · 2021Article
- Coatings in Decellularized Vascular Scaffolds for the Establishment of a Functional Endothelium: A Scoping Review of Vascular Graft Refinement.Frontiers in cardiovascular medicine · 2021Article
- A narrative review of vascular conduits for coronary artery bypass grafting.Cell transplantationReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Currently, despite the success of percutaneous coronary intervention (PCI), coronary artery bypass graft (CABG) remains among the most commonly performed cardiac surgical procedures in the United States. Unfortunately, the use of autologous grafts in CABG presents a major clinical challenge as complications due to autologous vessel harvest and limited vessel availability pose a significant setback in the success rate of CABG surgeries. Acellular extracellular matrix (ECM) scaffolds derived from xenogeneic vascular tissues have the potential to overcome these challenges, as they offer unlimited availability and sufficient length to serve as "off-the-shelf" CABGs. Unfortunately, regardless of numerous efforts to produce a fully functional small diameter xenogeneic ECM scaffold, the combination of factors required to overcome all failure mechanisms in a single graft remains elusive. This article covers the major failure mechanisms of current xenogeneic small diameter vessel ECM scaffolds, and reviews the recent advances in the field to overcome these failure mechanisms and ultimately develop a small diameter ECM xenogeneic scaffold for CABG. Impact Statement Currently, the use of autologous vessel in coronary artery bypass graft (CABG) is common practice. However, the use of autologous tissue poses significant complications due to tissue harvest and limited availability. Developing an alternative vessel for use in CABG can potentially increase the success rate of CABG surgery by eliminating complications related to the use of autologous vessel. However, this development has been hindered by an array of failure mechanisms that currently have not been overcome. This article describes the currently identified failure mechanisms of small diameter vascular xenogeneic extracellular matrix scaffolds and reviews current research targeted to overcoming these failure mechanisms toward ensuring long-term graft patency.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.