ArticleOrthopaedic surgery2019
Treatment of Femoral Neck Fractures with Cannulated Screw Invasive Internal Fixation Assisted by Orthopaedic Surgery Robot Positioning System.
Article in Orthopaedic surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
30 citing papers in PubMed, 5 syntheses or guidelines pooled it, 41 citations in OpenAlex.
- Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.Journal of robotic surgery · 2026Pooled it
- Advantages of TiRobot-assisted technology in internal fixation of femoral neck fractures: a meta-analysis of surgical parameters and complications.Journal of robotic surgery · 2025Pooled it
- Robot-assisted versus traditional surgery in the treatment of intertrochanteric fractures: a meta-analysis.Journal of robotic surgery · 2024Pooled it
- Comparison of rehabilitation outcomes between robot-assisted and freehand screw placement in treatment of femoral neck fractures: a systematic review and meta-analysis.BMC musculoskeletal disorders · 2024Pooled it
- Computer-assisted cannulated screw internal fixation versus conventional cannulated screw internal fixation for femoral neck fractures: a systematic review and meta-analysis.Journal of orthopaedic surgery and research · 2021Pooled it
- Comparing the outcome of pediatric femoral neck fracture between Ti-Robot surgery and traditional surgery.Journal of children's orthopaedics · 2026Article
- Emerging Technologies for Assisted Fracture Reduction: A Systematic Review.Annals of biomedical engineering · 2026Review
- Clinical efficacy of manual reverse closed reduction and robot-assisted cannulated screw fixation for valgus-impacted osteoporotic femoral neck fractures in the elderly: a retrospective cohort study.Frontiers in surgery · 2026Article
- Does Preoperative CT Improve Outcomes in Femoral Neck Fracture Fixation? A Retrospective Study.Journal of clinical medicine · 2025Article
- A comparative study of internal fixation with porous tantalum screws and cannulated screws in the treatment of femoral neck fractures.Scientific reports · 2025Article
- Research trends and hotspots of Colles fracture: a bibliometric analysis from 1980 to 2023.Frontiers in surgery · 2025Article
- Clinical and economic evaluation of robotic vs. freehand screw fixation in femoral neck fractures: advancing precision alignment in orthopedics.Frontiers in surgery · 2025Article
- Long-term outcome of robotic-guided closed reduction internal fixation for Delbet II femoral neck fractures in children.Journal of orthopaedic surgery and research · 2024Article
- Comparative Efficacy and Safety of Robot-Assisted vs. Freehand Screw Placement in Femoral Neck Fractures: An Updated Systematic Review and Meta-Analysis.Journal of clinical medicine · 2024Review
- Application of robot navigation system for insertion of femoral neck system in the treatment of femoral neck fracture.BMC musculoskeletal disorders · 2024Article
- A Novel Navigation Device for Precise Percutaneous Placement of the Guidewire in Femoral Neck Fracture Cannulated Screw Fixation Surgery.IEEE journal of translational engineering in health and medicine · 2024Article
- Global research status and trends in orthopaedic surgical robotics: a bibliometric and visualisation analysis study.Journal of robotic surgery · 2023Article
- [Computer-assisted procedures in orthopedics and trauma surgery-Where do we stand?]Chirurgie (Heidelberg, Germany) · 2023Review
- The role of microscopic properties on cortical bone strength of femoral neck.BMC musculoskeletal disorders · 2023Article
- Femoral neck system vs. cannulated screws on treating femoral neck fracture: a meta-analysis and system review.Frontiers in surgery · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo investigate the clinical efficacy and advantages of cannulated screw internal fixation assisted by the orthopaedic surgery robot positioning system in the treatment of femoral neck fractures.
methodsThe clinical data of 128 patients with femoral neck fractures which had been treated with cannulated screw internal fixation from January 2016 to July 2018 were retrospectively analyzed. Among them, 63 patients were treated with cannulated screw assisted by orthopedic robot positioning system (orthopaedic surgery robot group), and 65 patients were treated with traditional cannulated screw (traditional surgery group). The operation time, number of intraoperative fluoroscopy, number of guide needle placements, and the amount of operative blood loss were compared between the two groups. The success rate of one-time nail placement and the fracture healing rate were calculated. Fracture healing and internal fixation were observed. The hip joint function was evaluated by the Harris hip score 1 year after operation.
resultsAll patients were followed up for 12 to 24 months. The operation time was 65.70 ± 9.87 min in the robot group and 73.74 ± 9.78 min in the traditional group. The number of intraoperative fluoroscopy was 13.67 ± 4.39 times in the robot group and 17.09 ± 4.02 times in the traditional group. The number of guide needle placements was 9.95 ± 3.72 times in the robot group and 13.78 ± 4.39 times in the traditional surgery group. The success rate of one-time nail placement was 100% (63/63) in the robot group and 49.23% (32/65) in the traditional group. The amount of operative blood loss was 15.25 ± 6.21 mL in the robot group and 25.51 ± 6.97 mL in the traditional group. Compared with the traditional group, the robot group had shorter operation time, less fluoroscopy, less needle placement, less bleeding, and higher success rate of one-time nail placement. There was a significant difference between the two groups (P < 0.05). In the robot group, there was no infection, loosening of internal fixation, fracture displacement, and osteonecrosis of femoral head during the follow-up period. The fracture healing rate was 100% (63/63). In the traditional group, there were two cases of loosening of internal fixation and one case of osteonecrosis of femoral head during the follow-up period. The fracture healing rate was 100% (65/65). All patients were evaluated for hip joint function 1 year after operation. The Harris hip score in the robot group was 86.86 ± 4.74, and the Harris hip score in the traditional surgery group was 83.08 ± 5.44. Compared with the traditional group, the Harris hip score in the robot group was higher than that in the traditional group. There was significant difference between the two groups (P < 0.05). The excellent and good rate were 92.06% (58/63) in the robot group and 80% (52/65) in the traditional group. There was no significant difference between the two groups (P > 0.05).
conclusionCannulated screw internal fixation assisted by the orthopaedic surgery robot positioning system is an ideal method for the treatment of femoral neck fractures. This method has the advantages of relatively simple operation, more accurate screw placement during operation, high success rate of one-time nail placement, short operation time, less surgical trauma, less radiation, and good recovery of hip function.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.