Evidence map›Paper›PMID 31663277›Full record

ArticleOrthopaedic surgery2019

Treatment of Femoral Neck Fractures with Cannulated Screw Invasive Internal Fixation Assisted by Orthopaedic Surgery Robot Positioning System.

Xiao-Dong Wang, Hai Lan, Kai-Nan Li

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers, 5 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed, 5 pooled it
3.5field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 5 syntheses or guidelines pooled it, 41 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Xiao-Dong WangZunyi Medical University, Zunyi, Guizhou, China.ORCID https://orcid.org/0000-0002-6510-9539
Hai LanZunyi Medical University, Zunyi, Guizhou, China.ORCID https://orcid.org/0000-0003-0915-4551
Kai-Nan LiDepartment of Orthopaedics, Affiliated Hospital of Chengdu University, Chengdu, Sichuan, China.
Zunyi Medical University · CNChengdu University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo investigate the clinical efficacy and advantages of cannulated screw internal fixation assisted by the orthopaedic surgery robot positioning system in the treatment of femoral neck fractures.

methodsThe clinical data of 128 patients with femoral neck fractures which had been treated with cannulated screw internal fixation from January 2016 to July 2018 were retrospectively analyzed. Among them, 63 patients were treated with cannulated screw assisted by orthopedic robot positioning system (orthopaedic surgery robot group), and 65 patients were treated with traditional cannulated screw (traditional surgery group). The operation time, number of intraoperative fluoroscopy, number of guide needle placements, and the amount of operative blood loss were compared between the two groups. The success rate of one-time nail placement and the fracture healing rate were calculated. Fracture healing and internal fixation were observed. The hip joint function was evaluated by the Harris hip score 1 year after operation.

resultsAll patients were followed up for 12 to 24 months. The operation time was 65.70 ± 9.87 min in the robot group and 73.74 ± 9.78 min in the traditional group. The number of intraoperative fluoroscopy was 13.67 ± 4.39 times in the robot group and 17.09 ± 4.02 times in the traditional group. The number of guide needle placements was 9.95 ± 3.72 times in the robot group and 13.78 ± 4.39 times in the traditional surgery group. The success rate of one-time nail placement was 100% (63/63) in the robot group and 49.23% (32/65) in the traditional group. The amount of operative blood loss was 15.25 ± 6.21 mL in the robot group and 25.51 ± 6.97 mL in the traditional group. Compared with the traditional group, the robot group had shorter operation time, less fluoroscopy, less needle placement, less bleeding, and higher success rate of one-time nail placement. There was a significant difference between the two groups (P < 0.05). In the robot group, there was no infection, loosening of internal fixation, fracture displacement, and osteonecrosis of femoral head during the follow-up period. The fracture healing rate was 100% (63/63). In the traditional group, there were two cases of loosening of internal fixation and one case of osteonecrosis of femoral head during the follow-up period. The fracture healing rate was 100% (65/65). All patients were evaluated for hip joint function 1 year after operation. The Harris hip score in the robot group was 86.86 ± 4.74, and the Harris hip score in the traditional surgery group was 83.08 ± 5.44. Compared with the traditional group, the Harris hip score in the robot group was higher than that in the traditional group. There was significant difference between the two groups (P < 0.05). The excellent and good rate were 92.06% (58/63) in the robot group and 80% (52/65) in the traditional group. There was no significant difference between the two groups (P > 0.05).

conclusionCannulated screw internal fixation assisted by the orthopaedic surgery robot positioning system is an ideal method for the treatment of femoral neck fractures. This method has the advantages of relatively simple operation, more accurate screw placement during operation, high success rate of one-time nail placement, short operation time, less surgical trauma, less radiation, and good recovery of hip function.

Indexed as

Bone ScrewsAdultBlood Loss, SurgicalDisability EvaluationFemaleFemoral Neck FracturesFluoroscopyFracture Fixation, InternalFracture HealingHumansMaleMiddle AgedOperative TimeRetrospective StudiesRobotic Surgical ProceduresTreatment OutcomeCannulated screw internal fixationFemoral neck fracturesOrthopaedic surgery robot positioning system

Identifiers

PMID31663277
PMCPMC6819174
OpenAlexW2982291697

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.