ReviewOrthopaedic surgery2019
Mixed Reality Combined with Three-Dimensional Printing Technology in Total Hip Arthroplasty: An Updated Review with a Preliminary Case Presentation.
Review in Orthopaedic surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed, 2 syntheses or guidelines pooled it, 53 citations in OpenAlex.
- Augmented reality-assisted versus conventional total hip arthroplasty: a systematic review and meta-analysis.Journal of orthopaedic surgery and research · 2023Pooled it
- The effectiveness of virtual reality, augmented reality, and mixed reality training in total hip arthroplasty: a systematic review and meta-analysis.Journal of orthopaedic surgery and research · 2023Pooled it
- Use of extended reality, virtual reality, augmented reality and mixed reality in clinical practice, education and research in knee arthroplasty: A scoping review.Journal of experimental orthopaedics · 2026Article
- Implementation of an Intraoperative Augmented Reality Environment for Custom-Made Partial Pelvis Replacements-A Proof of Concept and Initial Results.Journal of personalized medicine · 2026Article
- Augmented Reality-Based Femur Registration With Head-Mounted Display and Infrared Tracking Device as Stand-Alone Navigation Tool: A Preclinical Validation Study.Health science reports · 2026Article
- Editorial: Exploring XR technologies for joint surgery: innovations and clinical applications.Frontiers in surgery · 2026Article
- Research progress on the application of mixed reality technology in femoral tunnel positioning during anterior cruciate ligament reconstruction.Frontiers in surgery · 2026Review
- Reconstruction of the Sternoclavicular Joint With an Autologous Fibular Head: A Case Report.Clinical case reports · 2025Article
- Case Report: 3D printing of customized combined guides assisting total hip arthroplasty for treatment of fused hip: a case report.Frontiers in bioengineering and biotechnology · 2025Article
- Application of digital model of mixed reality dynamic tracking technique in oral and maxillofacial surgery: a basic research.Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology · 2024Article
- Application of a novel osteotomy instrumentation as a substitute tool in total hip arthroplasty.BMC musculoskeletal disorders · 2022Article
- What's new in artificially intelligent joint surgery in China? The minutes of the 2021 IEEE ICRA and literature review.Arthroplasty (London, England) · 2022Review
- Mixed Reality Technology in Total Knee Arthroplasty: An Updated Review With a Preliminary Case Report.Frontiers in surgery · 2022Article
- Case report: Resection of a massive primary sacrococcygeal mature teratoma in an adult using 3-dimensional reconstruction and mixed reality technology.Frontiers in surgery · 2022Article
- Mixed reality for visualization of orthopedic surgical anatomy.World journal of orthopedics · 2021Article
- Registration Techniques for Clinical Applications of Three-Dimensional Augmented Reality Devices.IEEE journal of translational engineering in health and medicine · 2021Review
- Simulated operation combined with patient-specific instrumentation technology is superior to conventional technology for supramalleolar osteotomy: a retrospective comparative study.American journal of translational research · 2021Article
- The clinical application value of mixed-reality-assisted surgical navigation for laparoscopic nephrectomy.Cancer medicine · 2020Article
- Patient-specific instrument-assisted minimally invasive internal fixation of calcaneal fracture for rapid and accurate execution of a preoperative plan: A retrospective study.BMC musculoskeletal disorders · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
Three-dimensional (3D) printing technology, virtual reality, and augmented reality technology have been used to help surgeons to complete complex total hip arthroplasty, while their respective shortcomings limit their further application. With the development of technology, mixed reality (MR) technology has been applied to improve the success rate of complicated hip arthroplasty because of its unique advantages. We presented a case of a 59-year-old man with an intertrochanteric fracture in the left femur, who had received a prior left hip fusion. After admission to our hospital, a left total hip arthroplasty was performed on the patient using a combination of MR technology and 3D printing technology. Before surgery, 3D reconstruction of a certain bony landmark exposed in the surgical area was first performed. Then a veneer part was designed according to the bony landmark and connected to a reference registration landmark outside the body through a connecting rod. After that, the series of parts were made into a holistic reference registration instrument using 3D printing technology, and the patient's data for bone and surrounding tissue, along with digital 3D information of the reference registration instrument, were imported into the head-mounted display (HMD). During the operation, the disinfected reference registration instrument was installed on the selected bony landmark, and then the automatic real-time registration was realized by HMD through recognizing the registration landmark on the reference registration instrument, whereby the patient's virtual bone and other anatomical structures were quickly and accurately superimposed on the real body of the patient. To the best of our knowledge, this is the first report to use MR combined with 3D printing technology in total hip arthroplasty.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials