ArticlePloS one2019
Robust, real-time generic detector based on a multi-feature probabilistic method.
Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 23 citations in OpenAlex.
- Computational and Memory Efficiency in Heartbeat Rate Detection: A Review of ECG and PPG Techniques.Sensors (Basel, Switzerland) · 2026Article
- Exploring Computational Techniques in Preprocessing Neonatal Physiological Signals for Detecting Adverse Outcomes: Scoping Review.Interactive journal of medical research · 2024Article
- Early bradycardia detection and therapeutic interventions in preterm infant monitoring.Scientific reports · 2021Observational
- The hidden waves in the ECG uncovered revealing a sound automated interpretation method.Scientific reports · 2021Article
- Diagnosis of Neonatal Late-Onset Infection in Very Preterm Infant: Inter-Observer Agreement and International Classifications.International journal of environmental research and public health · 2021Article
- Analysis of Cardiac Vibration Signals Acquired From a Novel Implant Placed on the Gastric Fundus.Frontiers in physiology · 2021Article
- Quiet Sleep Organization of Very Preterm Infants Is Correlated With Postnatal Maturation.Frontiers in pediatrics · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Robust, real-time event detection from physiological signals acquired during long-term ambulatory monitoring still represents a major challenge for highly-artifacted signals. In this paper, we propose an original and generic multi-feature probabilistic detector (MFPD) and apply it to real-time QRS complex detection under noisy conditions. The MFPD method calculates a binary Bayesian probability for each derived feature and makes a centralized fusion, using the Kullback-Leibler divergence. The method is evaluated on two ECG databases: 1) the MIT-BIH arrhythmia database from Physionet containing clean ECG signals, 2) a benchmark noisy database created by adding noise recordings of the MIT-BIH noise stress test database, also from Physionet, to the MIT-BIH arrhythmia database. Results are compared with a well-known wavelet-based detector, and two recently published detectors: one based on spatiotemporal characteristic of the QRS complex and the second, as the MFDP, based on feature calculations from the University of New South Wales detector (UNSW). For both benchmark Physionet databases, the proposed MFPD method achieves the lowest standard deviation in sensitivity and positive predictivity (+P) despite its online algorithm architecture. While the statistics are comparable for low-to mildly artifactual ECG signals, the MFPD outperforms reference methods for artifacted ECG with low SNR levels reaching 87.48 ± 14.21% in sensitivity and 89.39 ± 14.67% in +P as compared to 88.30 ± 17.66% and 86.06 ± 19.67% respectively from UNSW, the best performing reference method. With demonstrations on the extensively studied QRS detection problem, we consider that the proposed generic structure of the multi-feature probabilistic detector should offer promising perspectives for long-term monitoring applications for highly-artifacted signals.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.