Evidence map›Paper›PMID 31661497›Full record

ArticlePloS one2019

Robust, real-time generic detector based on a multi-feature probabilistic method.

Matthieu Doyen, Di Ge, Alain Beuchée, Guy Carrault, Alfredo I Hernández

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Observational
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Matthieu DoyenUniv Rennes, CHU Rennes, Inserm, LTSI - UMR 1099, F-35000 Rennes, France.ORCID 0000-0003-4193-5331
Di GeUniv Rennes, CHU Rennes, Inserm, LTSI - UMR 1099, F-35000 Rennes, France.
Alain BeuchéeUniv Rennes, CHU Rennes, Inserm, LTSI - UMR 1099, F-35000 Rennes, France.
Guy CarraultUniv Rennes, CHU Rennes, Inserm, LTSI - UMR 1099, F-35000 Rennes, France.
Alfredo I HernándezUniv Rennes, CHU Rennes, Inserm, LTSI - UMR 1099, F-35000 Rennes, France.
Inserm · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Robust, real-time event detection from physiological signals acquired during long-term ambulatory monitoring still represents a major challenge for highly-artifacted signals. In this paper, we propose an original and generic multi-feature probabilistic detector (MFPD) and apply it to real-time QRS complex detection under noisy conditions. The MFPD method calculates a binary Bayesian probability for each derived feature and makes a centralized fusion, using the Kullback-Leibler divergence. The method is evaluated on two ECG databases: 1) the MIT-BIH arrhythmia database from Physionet containing clean ECG signals, 2) a benchmark noisy database created by adding noise recordings of the MIT-BIH noise stress test database, also from Physionet, to the MIT-BIH arrhythmia database. Results are compared with a well-known wavelet-based detector, and two recently published detectors: one based on spatiotemporal characteristic of the QRS complex and the second, as the MFDP, based on feature calculations from the University of New South Wales detector (UNSW). For both benchmark Physionet databases, the proposed MFPD method achieves the lowest standard deviation in sensitivity and positive predictivity (+P) despite its online algorithm architecture. While the statistics are comparable for low-to mildly artifactual ECG signals, the MFPD outperforms reference methods for artifacted ECG with low SNR levels reaching 87.48 ± 14.21% in sensitivity and 89.39 ± 14.67% in +P as compared to 88.30 ± 17.66% and 86.06 ± 19.67% respectively from UNSW, the best performing reference method. With demonstrations on the extensively studied QRS detection problem, we consider that the proposed generic structure of the multi-feature probabilistic detector should offer promising perspectives for long-term monitoring applications for highly-artifacted signals.

Indexed as

AlgorithmsBayes TheoremDatabases, FactualArrhythmias, CardiacElectrocardiographyHumansProbabilitySignal Processing, Computer-Assisted

Identifiers

PMID31661497
PMCPMC6818956
OpenAlexW2982392564

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.