Evidence map›Paper›PMID 31660983›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2019

Surveillance of abdominal aortic aneurysm using accelerated 3D non-contrast black-blood cardiovascular magnetic resonance with compressed sensing (CS-DANTE-SPACE).

Chengcheng Zhu, Lizhen Cao, Zhaoying Wen, Sinyeob Ahn, Esther Raithel, Christoph Forman, Michael Hope, David Saloner

Abstract readValidation Study
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Dark blood cardiovascular magnetic resonance of the heart, great vessels, and lungs using electrocardiographic-gated three-dimensional unbalanced steady-state free precession.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2021
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Chengcheng ZhuDepartment of Radiology and Biomedical Imaging, UCSF, 4150 Clement Street, San Francisco, CA, 94121, USA. zhucheng043@gmail.com.ORCID 0000-0001-6898-549X
Lizhen CaoDepartment of Radiology and Biomedical Imaging, UCSF, 4150 Clement Street, San Francisco, CA, 94121, USA.
Zhaoying WenDepartment of Radiology and Biomedical Imaging, UCSF, 4150 Clement Street, San Francisco, CA, 94121, USA. wenzhaoying11@163.com.
Sinyeob AhnSiemens Healthcare, San Francisco, CA, USA.
Esther RaithelSiemens Healthcare GmbH, Erlangen, Germany.
Christoph FormanSiemens Healthcare GmbH, Erlangen, Germany.
Michael HopeDepartment of Radiology and Biomedical Imaging, UCSF, 4150 Clement Street, San Francisco, CA, 94121, USA.
David SalonerDepartment of Radiology and Biomedical Imaging, UCSF, 4150 Clement Street, San Francisco, CA, 94121, USA.

Funding

MRI of Structure and Function in Assessing Hemodynamic Impact on AAA EvolutionR01HL114118 · NHLBI · NORTHERN CALIFORNIA INSTITUTE/RES/EDU · PI SALONER, DAVID A · 2014 to 2017
$1.8M
Hemodynamic and inflammatory imaging in evaluation of abdominal aortic aneurysmsR01HL123759 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI HOPE, MICHAEL DOUGLAS · 2015 to 2018
$1.6M
Characterization of intracranial vessel wall morphology and inflammation using 3D high resolution MRIK99HL136883 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI ZHU, CHENGCHENG · 2017 to 2018
$181k
NHLBI NIH HHS K99HL136883NHLBI NIH HHS R01 HL114118NHLBI NIH HHS R01HL114118NHLBI NIH HHS R01HL123759
6 · The paper itself

Abstract

background3D non-contrast high-resolution black-blood cardiovascular magnetic resonance (CMR) (DANTE-SPACE) has been used for surveillance of abdominal aortic aneurysm (AAA) and validated against computed tomography (CT) angiography. However, it requires a long scan time of more than 7 min. We sought to develop an accelerated sequence applying compressed sensing (CS-DANTE-SPACE) and validate it in AAA patients undergoing surveillance.

methodsThirty-eight AAA patients (all males, 73 ± 6 years) under clinical surveillance were recruited for this study. All patients were scanned with DANTE-SPACE (scan time 7:10 min) and CS-DANTE-SPACE (scan time 4:12 min, a reduction of 41.4%). Nine 9 patients were scanned more than 2 times. In total, 50 pairs of images were available for comparison. Two radiologists independently evaluated the image quality on a 1-4 scale, and measured the maximal diameter of AAA, the intra-luminal thrombus (ILT) and lumen area, ILT-to-muscle signal intensity ratio, and the ILT-to-lumen contrast ratio. The sharpness of the aneurysm inner/outer boundaries was quantified.

resultsCS-DANTE-SPACE achieved comparable image quality compared with DANTE-SPACE (3.15 ± 0.67 vs. 3.03 ± 0.64, p = 0.06). There was excellent agreement between results from the two sequences for diameter/area and ILT ratio measurements (ICCs> 0.85), and for quantifying growth rate (3.3 ± 3.1 vs. 3.3 ± 3.4 mm/year, ICC = 0.95.) CS-DANTE-SPACE showed a higher ILT-to-lumen contrast ratio (p = 0.01) and higher sharpness than DANTE-SPACE (p = 0.002). Both sequences had excellent inter-reader reproducibility for quantitative measurements (ICC > 0.88).

conclusionCS-DANTE-SPACE can reduce scan time while maintaining image quality for AAA imaging. It is a promising tool for the surveillance of patients with AAA disease in the clinical setting.

Indexed as

Imaging, Three-DimensionalMagnetic Resonance AngiographyAgedAorta, AbdominalAortic Aneurysm, AbdominalHumansMalePredictive Value of TestsReproducibility of ResultsTime FactorsWorkflowAbdominal aortic aneurysm, black blood CMRCompressed sensingPatient surveillance

Identifiers

PMID31660983
PMCPMC6816154

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.