ArticlePediatric cardiology2020
Comparison of Semi-Automated Versus Manual Quantitative Right Ventricular Assessment in Hypoplastic Left Heart Syndrome.
Article in Pediatric cardiology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Article
- Transthoracic echocardiographic assessment of ventricular function in functional single ventricle: a comprehensive review.Cardiovascular ultrasound · 2025Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Quantitative echocardiographic evaluation is important for systemic right ventricles, but its asymmetric shape makes this challenging and time consuming when performed manually. Semi-automated software could make these quantitative measures easier to accomplish in the clinical setting. We hypothesized that semi-automated software would approximate manual measures of right ventricular size and function. Children with hypoplastic left heart who had echocardiograms were prospectively identified. These measurements were performed using manual and semi-automated techniques: end-diastolic and end-systolic area, fractional area change (FAC), dimensions (longitudinal, basal and mid-cavitary diameters), and tricuspid annular plane systolic excursion (TAPSE). Agreement between measures was evaluated. Sixty-three echocardiograms were analyzed. Intra- and inter-observer reliability was acceptable and similar between methods except that inter-observer reliability for the manual method was superior for TAPSE. Correlation between methods was high (r > 0.9, p < 0.001) for most of the measures. Correlation for FAC was r = 0.79, and for TAPSE the correlation was r = 0.61 (both p < 0.001). The percent relative difference between manual and semi-automated methods was less than 6% for most measures. End-systolic area and FAC had a relative difference of 10% and 11% respectively. The only measure with substantial bias between the manual and semi-automated methods was TAPSE which had a relative difference of 52%. EchoInsight® semi-automated software provides similar measures of right ventricular dimensions and FAC in patients with hypoplastic left heart compared to manual measures. Measures of TAPSE do not correlate well between manual and semi-automated methods. Further research is warranted on the use of semi-automated analyses in this patient population.