Evidence map›Paper›PMID 31655900›Full record

ArticleMikrochimica acta2019

Sensing of cocaine using polarized optical microscopy by exploiting the conformational changes of an aptamer at the water/liquid crystal interface.

Shihong Wang, Guannan Zhang, Qianshan Chen, Jun Zhou, Zhaoyang Wu

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Shihong WangState Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, People's Republic of China.
Guannan ZhangState Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, People's Republic of China.
Qianshan ChenState Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, People's Republic of China.
Jun ZhouState Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, People's Republic of China.
Zhaoyang WuState Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, People's Republic of China. zywu@hnu.edu.cn.ORCID http://orcid.org/0000-0002-3188-9864
Hunan University · CN

Funding

the International Scientific and Technological Cooperation Projects of China 2012DFR40480the National Natural Science Foundation of China 21675045the National Natural Science Foundation of China 21874037
6 · The paper itself

Abstract

Liquid crystals (LCs) have the ability to transduce and amplify a molecular stimulus into optical signals due to their elastic and birefringence properties. An aptamer-based LC sensor for cocaine is described here. 3-Morpholinopropanesulfonic acid with amphipathic structure was used to establish recognition sites at a water/LC interface for the detection of cocaine. The cocaine-binding aptamer is formed at the interface. The conformation of the aptamer undergoes a change on binding cocaine, and this triggers the LCs anchoring transition from homeotropic to planar. Binding can also be detected by polarized optical microscopy. The fluorescence spectroscopy and circular dichroism results are used to prove that the conformation of aptamer changed from a hairpin structure to a special three-way junction structure on binding of cocaine at the interface. The assay works in the 1 nM to 10 μM cocaine concentration range and is specific. Graphical abstract Schematic representation of aptamer-based liquid crystal (LC) biosensor for the detection of cocaine. In this interface biosensing system, after the aptamer binding with cocaine, the conformation of aptamer at the aqueous/LC interface was changed from a hairpin structure to a special three-way junction structure. This triggered the Liquid crystals (LCs) anchoring transition from homeotropic to planar and the sign-on optical signal could be obtained by polarizing optical microscope (POM) in real-time.

Indexed as

Anchoring transitionAverage grayscale valueCircular dichroismConformation transitionFluorescence spectraLiquid crystal biosensorOptical imagesOptical signalUrine

Identifiers

PMID31655900
OpenAlexW2982034079

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.