ArticleJournal of clinical medicine2019
Noninvasive and Convenient Screening of Metabolic Syndrome Using the Controlled Attenuation Parameter Technology: An Evaluation Based on Self-Paid Health Examination Participants.
Article in Journal of clinical medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 18 citations in OpenAlex.
- Association Between Fatty Liver Index, Controlled Attenuation Parameter, and Metabolic Syndrome Stages: A Community-Based Study.Medical science monitor : international medical journal of experimental and clinical research · 2023Article
- Machine-Learning Algorithm for Predicting Fatty Liver Disease in a Taiwanese Population.Journal of personalized medicine · 2022Article
- Intermittent Hypoxic-Hyperoxic Exposures Effects in Patients with Metabolic Syndrome: Correction of Cardiovascular and Metabolic Profile.Biomedicines · 2022Article
- Association between liver stiffness measurement by transient elastography and chronic kidney disease.Medicine · 2022Article
- A COVID-19 Pandemic Artificial Intelligence-Based System With Deep Learning Forecasting and Automatic Statistical Data Acquisition: Development and Implementation Study.Journal of medical Internet research · 2021Article
- Article
- Identify the Characteristics of Metabolic Syndrome and Non-obese Phenotype: Data Visualization and a Machine Learning Approach.Frontiers in medicine · 2021Article
- Validation of Controlled Attenuation Parameter Measured by FibroScan as a Novel Surrogate Marker for the Evaluation of Metabolic Derangement.Frontiers in endocrinology · 2021Article
- Development of an Online Health Care Assessment for Preventive Medicine: A Machine Learning Approach.Journal of medical Internet research · 2020Article
- Predicting Metabolic Syndrome With Machine Learning Models Using a Decision Tree Algorithm: Retrospective Cohort Study.JMIR medical informatics · 2020Article
- Clustering Heatmap for Visualizing and Exploring Complex and High-dimensional Data Related to Chronic Kidney Disease.Journal of clinical medicine · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundThere is a medical need for an easy, fast, and non-invasive method for metabolic syndrome (MetS) screening. This study aimed to assess the ability of FibroScan to detect MetS, in participants who underwent a self-paid health examination.
methodsA retrospective cohort study was conducted on all adults who underwent a self-paid health examination comprising of an abdominal transient elastography inspection using FibroScan 502 Touch from March 2015 to February 2019. FibroScan can assess the level of liver fibrosis by using a liver stiffness score, and the level of liver steatosis by using the controlled attenuation parameter (CAP) score. The logistic regression analysis and receiver operating characteristic curve were applied to select significant predictors and assess their predictability. A final model that included all significant predictors that are found by univariate analysis, and a convenient model that excluded all invasive parameters were created.
resultsOf 1983 participants, 13.6% had a physical status that fulfilled MetS criteria. The results showed that the CAP score solely could achieve an area under the curve (AUC) of 0.79 (0.76-0.82) in predicting MetS, and the AUC can be improved to 0.88 (0.85-0.90) in the final model. An AUC of 0.85 (0.83-0.88) in predicting MetS was obtained in the convenient model, which includes only 4 parameters (CAP score, gender, age, and BMI). A panel of predictability indices (the ranges of sensitivity, specificity, positive and negative likelihood ratio: 0.78-0.89, 0.66-0.82, 2.64-4.47, and 0.17-0.26) concerning gender- and BMI-specific CAP cut-off values (range: 191.65-564.95) were presented for practical reference.
conclusionsTwo prediction systems were proposed for identifying individuals with a physical status that fulfilled the MetS criteria, and a panel of predictability indices was presented for practical reference. Both systems had moderate predictive performance. The findings suggested that FibroScan evaluation is appropriate as a first-line MetS screening; however, the variation in prediction performance of such systems among groups with varying metabolic derangements warrants further studies in the future.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.