ArticleSensors (Basel, Switzerland)2019
Dynamic Response of Elastomer-Based Liquid-Filled Variable Focus Lens.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Multi-Wavelength Achromatic 3D Meta-holography with Zoom Function.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Electrochemical Coupled Analysis of a Micro Piezo-Driven Focusing Mechanism.Micromachines · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Variable focus lenses are capable of dynamically varying their focal lengths. The focal length is varied by adjusting the curvature of the refractive surface and the media on both sides of the lens. The dynamic response is one of the most important criteria to determine the performance of variable focus lens. In this work, we investigated critical factors that affect the dynamic response of liquid-filled variable focus lens with a large aperture size. Based on a theoretical analysis of a circular disk representative of a deformable surface, we found that the dynamic response is significantly influenced by the diameter, thickness, and stiffness of the disk because these factors determine its first natural frequency. We also studied the dynamic response of elastomer-based liquid-filled variable focus lens prototype with different aperture sizes (20 and 30 mm) by using experiments and we found that the lens with the smaller aperture size had an excellent dynamic response.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.