Evidence map›Paper›PMID 31653002›Full record

ArticleJournal of clinical medicine2019

Analysis of Pulse Arrival Time as an Indicator of Blood Pressure in a Large Surgical Biosignal Database: Recommendations for Developing Ubiquitous Blood Pressure Monitoring Methods.

Joonnyong Lee, Seungman Yang, Saram Lee, Hee Chan Kim

Abstract read
In one paragraph

Article in Journal of clinical medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Exploring the Effect of LED-to-Photodetector Spacing on Subcutaneous Photoplethysmography for Continuous Blood Pressure Measurement.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2025
    Article
  5. Article
  6. Article
  7. Article
  8. Quantifying the Suitability of Biosignals Acquired During Surgery for Multimodal Analysis.IEEE open journal of engineering in medicine and biology · 2024
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Review
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Joonnyong LeeSeoul National University Hospital Biomedical Research Institute, Seoul 03080, Korea. joonnyonglee@melab.snu.ac.kr.ORCID 0000-0002-3642-9891
Seungman YangInterdisciplinary Program in Bioengineering, Seoul National University Graduate School, Seoul 03080, Korea. ysmgreen@melab.snu.ac.kr.
Saram LeeSeoul National University Hospital Biomedical Research Institute, Seoul 03080, Korea. hommelee@snu.ac.kr.
Hee Chan KimDepartment of Biomedical Engineering, College of Medicine, Seoul National University, Seoul 03080, Korea. hckim@snu.ac.kr.ORCID 0000-0002-2112-426X

Funding

Bio and Medical Technology Development Program of the National Research Foundation (NRF) funded by the Korean Government (MSIT) 2016M3A9F1939646
6 · The paper itself

Abstract

As non-invasive continuous blood pressure monitoring (NCBPM) has gained wide attraction in the recent decades, many pulse arrival time (PAT) or pulse transit time (PTT) based blood pressure (BP) estimation studies have been conducted. However, most of the studies have used small homogeneous subject pools to generate models of BP based on particular interventions for induced hemodynamic change. In this study, a large open biosignal database from a diverse group of 2309 surgical patients was analyzed to assess the efficacy of PAT, PTT, and confounding factors on the estimation of BP. After pre-processing the dataset, a total of 6,777,308 data pairs of BP and temporal features between electrocardiogram (ECG) and photoplethysmogram (PPG) were extracted and analyzed. Correlation analysis revealed that PAT or PTT extracted from the intersecting-tangent (IT) point of PPG showed the highest mean correlation to BP. The mean correlation between PAT and systolic blood pressure (SBP) was -0.37 and the mean correlation between PAT and diastolic blood pressure (DBP) was -0.30, outperforming the correlation between BP and PTT at -0.12 for SBP and -0.11 for DBP. A linear model of BP with a simple calibration method using PAT as a predictor was developed which satisfied international standards for automatic oscillometric BP monitors in the case of DBP, however, SBP could not be predicted to a satisfactory level due to higher errors. Furthermore, multivariate regression analyses showed that many confounding factors considered in previous studies had inconsistent effects on the degree of correlation between PAT and BP.

Indexed as

biosignal databaseblood pressure monitoringcardiovascular monitoringhypertensionpulse arrival timepulse transit timepulse wave velocityubiquitous healthcare

Identifiers

PMID31653002
PMCPMC6912522

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.