Evidence map›Paper›PMID 31652574›Full record

ArticleSensors (Basel, Switzerland)2019

Passively Addressable Ultra-Low Volume Sweat Chloride Sensor.

Antra Ganguly, Shalini Prasad

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Antra GangulyDepartment of Bioengineering, University of Texas at Dallas, 800 West Campbell Road, Richardson, TX 75080, USA. Antra.Ganguly@utdallas.edu.
Shalini PrasadDepartment of Bioengineering, University of Texas at Dallas, 800 West Campbell Road, Richardson, TX 75080, USA. Shalini.Prasad@utdallas.edu.ORCID 0000-0002-2404-3801

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This work demonstrates a novel electrochemical biosensor for the detection of chloride ion levels in ultra-low volumes (1-3 microliters) of passively expressed human sweat. We present here a hydration monitor that the pediatric, geriatric, and other immune-compromised or physically inactive/sedentary population cohort can utilize, for whom the current methods of chloride quantification of active stimulation of sweat glands through iontophoresis or treadmill runs are unsuitable. In this work, non-faradaic electroanalysis using gold microelectrodes deposited on a flexible nanoporous substrate, for high nanoscale surface area to volume enhancement, was leveraged to operate in ultra-low sweat volumes of <3 µL eluted at natural rates. The specific chloride ionophore-based affinity of chloride ions resulted in the modulation of charge transfer within the electrical double layer at the electrode-sweat buffer interface, which was transduced using electrochemical impedance spectroscopy (EIS) and chronoamperometry (CA). Linear calibration dose responses with R-squared values of 0.9746 and 0.9403 for EIS and CA respectively were obtained for a dynamic range of 10-100 mM. The surface charge and the binding chemistry of the capture probe were studied using zeta potential studies and UV-Vis. The dynamic sweat chloride-tracking capability of the sensor was evaluated for a duration of 180 min. Studies were conducted to probe the efficacy of the developed sensor for passive ultra-low sweat chloride assessment on human subjects (n = 3).

Indexed as

Biosensing TechniquesBuffersCalibrationChloridesDielectric SpectroscopyElectrochemical TechniquesHumansHydrogen-Ion ConcentrationStatic ElectricitySweatBuffersChlorideschloride ionophorechronoamperometrycontinuous monitoringnon-faradaic electrochemical impedance spectroscopysweat chloride sensorwearables

Identifiers

PMID31652574
PMCPMC6833906

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.