Trial reportEuropean journal of anaesthesiology2019
Glottic visibility for laryngeal surgery: Tritube vs. microlaryngeal tube: A randomised controlled trial.
Trial report in European journal of anaesthesiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 1 synthesis or guideline pooled it, 30 citations in OpenAlex.
- Oncological and Functional Outcomes of Transoral Robotic Surgery and Endoscopic Laryngopharyngeal Surgery for Hypopharyngeal Cancer: A Systematic Review.Frontiers in surgery · 2021Pooled it
- Control of the expiratory flow in a lung model and in healthy volunteers with an adjustable flow regulator: a combined bench and randomized crossover study.Respiratory research · 2021Trial
- Apnoeic oxygenation with high-flow nasal oxygen in adult patients undergoing endoscopic pharyngolaryngeal surgery: a clinical review.European journal of anaesthesiology and intensive care · 2026Review
- Prolonged Flow-Controlled Ventilation in a Patient With ARDS and Multiple Trauma: A Case Report.Chest · 2025Article
- Airway management during unusual tracheal stenosis: A clinical feasibility trial.Laryngoscope investigative otolaryngology · 2023Article
- Count in Time So All is Fine.Indian journal of otolaryngology and head and neck surgery : official publication of the Association of Otolaryngologists of India · 2023Article
- Perioperative lung function following flow controlled ventilation for robot-assisted prostatectomies in steep trendelenburg position: an observational study.Intensive care medicine experimental · 2023Article
- A new perspective during laryngo-tracheal surgery: the use of an ultra-thin endotracheal tube (Tritube®) and flow-controlled ventilation-a retrospective case series and a review of the literature.Journal of anesthesia, analgesia and critical care · 2022Article
- Novel ventilation techniques in children.Paediatric anaesthesia · 2022Review
- Flow-controlled ventilation maintains gas exchange and lung aeration in a pediatric model of healthy and injured lungs: A randomized cross-over experimental study.Frontiers in pediatrics · 2022Article
- Flow-controlled ventilation - a new and promising method of ventilation presented with a review of the literature.Anaesthesiology intensive therapy · 2022Review
- Experience with Tritube and Flow-Controlled Ventilation During Airway Surgery.Turkish journal of anaesthesiology and reanimation · 2021Article
- A case report of individualized ventilation in a COVID-19 patient - new possibilities and caveats to consider with flow-controlled ventilation.BMC anesthesiology · 2021Article
- Flow-controlled ventilation during EVLP improves oxygenation and preserves alveolar recruitment.Intensive care medicine experimental · 2020Article
- Individualized flow-controlled ventilation compared to best clinical practice pressure-controlled ventilation: a prospective randomized porcine study.Critical care (London, England) · 2020Article
- Bronchoscope-assisted Tritube® placement for resection of sequential tracheal stenosis.Anaesthesia reportsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundGood visibility is essential for successful laryngeal surgery. A Tritube with outer diameter 4.4 mm, combined with flow-controlled ventilation (FCV), enables ventilation by active expiration with a sealed trachea and may improve laryngeal visibility.
objectivesWe hypothesised that a Tritube with FCV would provide better laryngeal visibility and surgical conditions for laryngeal surgery than a conventional microlaryngeal tube (MLT) with volume-controlled ventilation (VCV).
designRandomised, controlled trial.
settingUniversity Medical Centre. PATIENTS: A total of 55 consecutive patients (>18 years) undergoing elective laryngeal surgery were assessed for participation, providing 40 evaluable data sets with 20 per group.
interventionsRandom allocation to intubation with Tritube and ventilation with FCV (Tritube-FCV group) or intubation with MLT 6.0 and ventilation with VCV (MLT-VCV) as control. Tidal volumes of 7 ml kg predicted body weight, and positive end-expiratory pressure of 7 cmH2O were standardised between groups.
main outcome measuresPrimary endpoint was the tube-related concealment of laryngeal structures, measured on videolaryngoscopic photographs by appropriate software. Secondary endpoints were surgical conditions (categorical four-point rating scale), respiratory variables and change of end-expiratory lung volume from atmospheric airway pressure to ventilation with positive end-expiratory pressure. Data are presented as median [IQR].
resultsThere was less concealment of laryngeal structures with the Tritube than with the MLT; 7 [6 to 9] vs. 22 [18 to 27] %, (P < 0.001). Surgical conditions were rated comparably (P = 0.06). A subgroup of residents in training perceived surgical conditions to be better with the Tritube compared with the MLT (P = 0.006). Respiratory system compliance with the Tritube was higher at 61 [52 to 71] vs. 46 [41 to 51] ml cmH2O (P < 0.001), plateau pressure was lower at 14 [13 to 15] vs. 17 [16 to 18] cmH2O (P < 0.001), and change of end-expiratory lung volume was higher at 681 [463 to 849] vs. 414 [194 to 604] ml, (P = 0.023) for Tritube-FCV compared with MLT-VCV.
conclusionDuring laryngeal surgery a Tritube improves visibility of the surgical site but not surgical conditions when compared with a MLT 6.0. FCV improves lung aeration and respiratory system compliance compared with VCV. TRIAL REGISTRY NUMBER: DRKS00013097.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.