ArticleJournal of diabetes science and technology2020

System Accuracy Assessment of a Combined Invasive and Noninvasive Glucometer.

Andreas Pfützner, Filiz Demircik, Johannes Pfützner, Kim Kessler, Stephanie Strobl, Jan Spatz, Anke H Pfützner, Alexander Lier

Abstract readComparative Study
In one paragraph

Article in Journal of diabetes science and technology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Andreas PfütznerPfützner Science & Health Institute, Mainz, Germany.ORCID 0000-0003-2385-0887
Filiz DemircikPfützner Science & Health Institute, Mainz, Germany.
Johannes PfütznerPfützner Science & Health Institute, Mainz, Germany.
Kim KesslerTechnical University, Department of Life Sciences, Bingen, Germany.
Stephanie StroblPfützner Science & Health Institute, Mainz, Germany.
Jan SpatzPfützner Science & Health Institute, Mainz, Germany.
Anke H PfütznerSciema UG, Mainz, Germany.
Alexander LierPfützner Science & Health Institute, Mainz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe pain associated with pricking the fingertip for blood glucose self-testing is considered to be a major burden in diabetes treatment. This study was performed to evaluate the system accuracy of the invasive TensorTip Combo Glucometer (CoG) device component in accordance with ISO15197:2015 requirements and to explore the accuracy of the noninvasive tissue glucose prediction component.

methodsOne hundred samples were obtained from people with type 1 and type 2 diabetes and healthy volunteers (43 females, 57 males; age: 53 ± 16 years), with glucose distribution as requested by the ISO standard. Three strip lots were tested twice by healthcare professionals in comparison to YSI 2300 Stat Plus reference method followed by a noninvasive tissue glucose reading (NI-CoG). Mean Absolute (Relative) Difference (MARD) was calculated and a consensus error grid (CEG) analysis was performed.

resultsThe ISO system accuracy criteria were met with the invasive strip technology by 586/600 of the data points (97.1%) and for each strip lot separately. All invasive results (100%) were within CEG-zone A and total MARD was calculated to be 7.1%. With the noninvasive reading, 99% of raw data points were in A + B (91.1% and 7.8%), and the total MARD was calculated to be 18.1%. DISCUSSION: The invasive component of the CoG device was shown to be in full compliance with the current ISO15197 criteria. Good results were also obtained with the NI-CoG tissue glucose prediction. This noninvasive technology would potentially be suitable for frequent pain-free glucose monitoring in many people with diabetes.

Indexed as

Reagent StripsAdultAgedBiomarkersBlood GlucoseBlood Glucose Self-MonitoringCase-Control StudiesCross-Sectional StudiesDiabetes Mellitus, Type 1Diabetes Mellitus, Type 2Equipment DesignFemaleHumansMaleMiddle AgedPredictive Value of TestsBiomarkersBlood GlucoseReagent Stripsinvasive blood glucose measurementnoninvasive glucose tissue predictionpatient blood glucose self-testingsystem accuracy

Identifiers

PMID31640424
PMCPMC7576942

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.