Evidence map›Paper›PMID 31640243›Full record

ArticleMaterials (Basel, Switzerland)2019

New Dental Implant with 3D Shock Absorbers and Tooth-Like Mobility-Prototype Development, Finite Element Analysis (FEA), and Mechanical Testing.

Avram Manea, Grigore Baciut, Mihaela Baciut, Dumitru Pop, Dan Sorin Comsa, Ovidiu Buiga, Veronica Trombitas, Horatiu Colosi, Ileana Mitre, Roxana Bordea and 4 more

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Avram ManeaDepartment of Cranio-Maxillofacial Surgery and Radiology, Faculty of Dental Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. avram.manea@umfcluj.ro.
Grigore BaciutDepartment of Cranio-Maxillofacial Surgery and Radiology, Faculty of Dental Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. gbaciut@umfcluj.ro.
Mihaela BaciutDepartment of Oral Rehabilitation, Faculty of Dental Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. mbaciut@yahoo.com.
Dumitru PopDepartment of Mechanical Systems Engineering, Faculty of Machine Building, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania. pdcluj@gmail.com.
Dan Sorin ComsaDepartment of Manufacturing Engineering, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania. dscomsa@tcm.utcluj.ro.
Ovidiu BuigaDepartment of Mechanical Systems Engineering, Faculty of Machine Building, Technical University of Cluj-Napoca, 400114 Cluj-Napoca, Romania. ovidiu.buiga@omt.utcluj.ro.
Veronica TrombitasDepartment of Cranio-Maxillofacial Surgery and Radiology, Faculty of Dental Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. veronicatrombitas@gmail.com.
Horatiu ColosiDepartment of Medical Education, Faculty of Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. hcolosi@umfcluj.ro.ORCID 0000-0002-9675-2893
Ileana MitreDepartment of Cranio-Maxillofacial Surgery and Radiology, Faculty of Dental Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. ilmitre@yahoo.com.
Roxana BordeaDepartment of Oral Rehabilitation, Faculty of Dental Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. roxana.bordea@ymail.com.
Marius ManoleDepartment of Prosthetics and Dental Materials, Faculty of Dental Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. mnole22@yahoo.com.
Manuela LenghelDepartment of Surgical specialties, Faculty of Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. lenghel.manuela@gmail.com.
Simion BranDepartment of Oral Rehabilitation, Faculty of Dental Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. dr_brans@umfcluj.ro.
Florin OnisorDepartment of Cranio-Maxillofacial Surgery and Radiology, Faculty of Dental Medicine, University of Medicine and Pharmacy 'Iuliu Hatieganu', 400012 Cluj-Napoca, Romania. florin.onisor@umfcluj.ro.

Funding

REHABILITATIVE NURSING INTERVENTIONS IN ELDERLY PATIENTS WITH HIP FRACTUREZ01AG000610 · NIA · AGING · PI MYERS, A H · 1994 to 1995
–
'Iuliu Hațieganu' University of Medicine and Pharmacy, Cluj-Napoca, Romania 22714/5/06.10.2011'Iuliu Hațieganu' University of Medicine and Pharmacy, Cluj-Napoca, Romania PCD 7690/67/15.04.2016
6 · The paper itself

Abstract

backgroundOnce inserted and osseointegrated, dental implants become ankylosed, which makes them immobile with respect to the alveolar bone. The present paper describes the development of a new and original implant design which replicates the 3D physiological mobility of natural teeth. The first phase of the test followed the resistance of the implant to mechanical stress as well as the behavior of the surrounding bone. Modifications to the design were made after the first set of results. In the second stage, mechanical tests in conjunction with finite element analysis were performed to test the improved implant design.

methodsIn order to test the new concept, 6 titanium alloy (Ti6Al4V) implants were produced (milling). The implants were fitted into the dynamic testing device. The initial mobility was measured for each implant as well as their mobility after several test cycles. In the second stage, 10 implants with the modified design were produced. The testing protocol included mechanical testing and finite element analysis.

resultsThe initial testing protocol was applied almost entirely successfully. Premature fracturing of some implants and fitting blocks occurred and the testing protocol was readjusted. The issues in the initial test helped design the final testing protocol and the new implants with improved mechanical performance.

conclusionThe new prototype proved the efficiency of the concept. The initial tests pointed out the need for design improvement and the following tests validated the concept.

Indexed as

biomaterialsdental implantfatigue testfinite element analysisISO 14801titanium

Identifiers

PMID31640243
PMCPMC6829458

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.