ArticleSensors (Basel, Switzerland)2019
Dropping Counter: A Detection Algorithm for Identifying Odour-Evoked Responses from Noisy Electroantennograms Measured by a Flying Robot.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
The electroantennogram (EAG) is a technique used for measuring electrical signals from the antenna of an insect. Its rapid response time, quick recovery speed, and high sensitivity make it suitable for odour-tracking tasks employing mobile robots. However, its application to flying robots has not been extensively studied owing to the electrical and mechanical noises generated. In this study, we investigated the characteristics of the EAG mounted on a tethered flying quadcopter and developed a special counter-based algorithm for detecting the odour-generated responses. As the EAG response is negative, the algorithm creates a window and compares the values inside it. Once a value is smaller than the first one, the counter will increase by one and finally turns the whole signal into a clearer odour stimulated result. By experimental evaluation, the new algorithm gives a higher cross-correlation coefficient when compared with the fixed-threshold method. The result shows that the accuracy of this novel algorithm for recognising odour-evoked EAG signals from noise exceeds that of the traditional method; furthermore, the use of insect antennae as odour sensors for flying robots is demonstrated to be feasible.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.