Comparison of manual and automated auscultatory blood pressure during graded exercise among people with type 2 diabetes.

Myles N Moore, Dean S Picone, Michele L Callisaya, Velandai Srikanth, James E Sharman, Martin G Schultz

Erratum issuedAbstract readClinical TrialComparative Study
In one paragraph

Trial report in Journal of clinical hypertension (Greenwich, Conn.), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. [Design and validation of an automated testing system for essential performance parameters of ventilators].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
  3. Assessing the strengths and limitations of non-invasive blood pressure measurement.Journal of clinical hypertension (Greenwich, Conn.) · 2023
    Article
  4. Article
  5. Review
  6. Corrigendum.Journal of clinical hypertension (Greenwich, Conn.) · 2020
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Myles N MooreMenzies Institute for Medical Research, College of Health and Medicine, University of Tasmania, Hobart, Tas, Australia.
Dean S PiconeMenzies Institute for Medical Research, College of Health and Medicine, University of Tasmania, Hobart, Tas, Australia.
Michele L CallisayaMenzies Institute for Medical Research, College of Health and Medicine, University of Tasmania, Hobart, Tas, Australia.
Velandai SrikanthCentral Clinical School, Faculty of Medicine, Monash University, Melbourne, Vic, Australia.
James E SharmanMenzies Institute for Medical Research, College of Health and Medicine, University of Tasmania, Hobart, Tas, Australia.
Martin G SchultzMenzies Institute for Medical Research, College of Health and Medicine, University of Tasmania, Hobart, Tas, Australia.ORCID 0000-0003-3458-1811

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Manual measurement of blood pressure (BP) during exercise testing is the recommended standard. Automated measurement of BP is an alternative method used during clinical exercise testing, but there is little data comparing manual and automated BP in this setting. The aim of this study was to determine the concordance between manual and automated BP during a standard clinical treadmill exercise test. 416 participants (66 ± 5 years; 54% male) completed a Bruce treadmill exercise test at baseline or follow-up within a clinical trial of participants with type 2 diabetes mellitus. Manual and automated BP were measured simultaneously at each exercise test stage. Manual BP was measured by a technician blinded to automated BP values (Tango+, Suntech). Concordance between manual and automated BP was assessed using mean differences and intraclass correlations (ICC). Concordance between manual and automated BP across all exercise stages was excellent for systolic BP (overall mean difference: 3 ± 11 mm Hg, P = .598; ICC = 0.964 [95% CI 0.942-0.977] and pulse pressure (overall mean difference: 2 ± 14 mm Hg, P = .595; ICC = 0.934 [95% CI 0.899-0.956]). Concordance between manual and automated diastolic BP across all exercise stages was moderate-to-good (overall mean difference: 1 ± 9 mm Hg, P = .905; ICC = 0.784 [95% CI 0.672-0.858]). Automated BP using the Tango + device is concordant with manual BP during early stages of a standard clinical exercise test. Thus, this automated method may be a suitable alternative to manual measurement of BP during clinical exercise testing.

Indexed as

AgedAuscultationAutomationBlood PressureBlood Pressure DeterminationDiabetes Mellitus, Type 2ExerciseExercise TestFemaleHumansHypertensionMaleMiddle AgedOxygen ConsumptionSensitivity and Specificitydiagnostic techniques and proceduresergometryexercise blood pressure

Identifiers

PMID31638321
PMCPMC8030525

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.