ArticleJournal of biomechanical engineering2019
Ex Vivo Mechanical Tests and Multiscale Computational Modeling Highlight the Importance of Intramural Shear Stress in Ascending Thoracic Aortic Aneurysms.
Article in Journal of biomechanical engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 27 citations in OpenAlex.
- Ascending aortic aneurysm growth in the Fbln4Biomechanics and modeling in mechanobiology · 2025Article
- Dissection Propagation via Avalanches in Human Descending Thoracic Aorta: Effect of Aging.Acta biomaterialia · 2025Article
- A multiscale discrete fiber model of failure in heterogeneous tissues: Applications to remodeled cerebral aneurysms.Journal of biomechanics · 2025Article
- Non-invasive estimation of material properties of normal and dissected human ascending aortasFrontiers in bioengineering and biotechnology · 2025Article
- Mechanical Models of Collagen Networks for Understanding Changes in the Failure Properties of Aging Skin.Journal of biomechanical engineering · 2024Article
- Atherosclerotic Calcifications Have a Local Effect on the Peel Behavior of Human Aortic Media.Journal of biomechanical engineering · 2024Article
- The non-affine fiber network solver: A multiscale fiber network material model for finite-element analysis.Journal of the mechanical behavior of biomedical materials · 2023Article
- A discrete fiber network finite element model of arterial elastin network considering inter-fiber crosslinking property and density.Journal of the mechanical behavior of biomedical materials · 2022Article
- Experimental and Mouse-Specific Computational Models of the Fbln4Cardiovascular engineering and technology · 2022Article
- Multiscale Computational Model Predicts Mouse Skin Kinematics Under Tensile Loading.Journal of biomechanical engineering · 2022Article
- A Hybrid Microstructural-Continuum Multiscale Approach for Modeling Hyperelastic Fibrous Soft Tissue.Journal Of Elasticity · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
Ascending thoracic aortic aneurysms (ATAAs) are anatomically complex in terms of architecture and geometry, and both complexities contribute to unpredictability of ATAA dissection and rupture in vivo. The goal of this work was to examine the mechanism of ATAA failure using a combination of detailed mechanical tests on human tissue and a multiscale computational model. We used (1) multiple, geometrically diverse, mechanical tests to characterize tissue properties; (2) a multiscale computational model to translate those results into a broadly usable form; and (3) a model-based computer simulation of the response of an ATAA to the stresses generated by the blood pressure. Mechanical tests were performed in uniaxial extension, biaxial extension, shear lap, and peel geometries. ATAA tissue was strongest in circumferential extension and weakest in shear, presumably because of the collagen and elastin in the arterial lamellae. A multiscale, fiber-based model using different fiber properties for collagen, elastin, and interlamellar connections was specified to match all of the experimental data with one parameter set. Finally, this model was used to simulate ATAA inflation using a realistic geometry. The predicted tissue failure occurred in regions of high stress, as expected; initial failure events involved almost entirely interlamellar connections, consistent with arterial dissection-the elastic lamellae remain intact, but the connections between them fail. The failure of the interlamellar connections, paired with the weakness of the tissue under shear loading, is suggestive that shear stress within the tissue may contribute to ATAA dissection.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.