Evidence map›Paper›PMID 31632981›Full record

ArticleFrontiers in surgery2019

Prospective Validation of Facial Nerve Monitoring to Prevent Nerve Damage During Robotic Drilling.

Juan Ansó, Cilgia Dür, Mareike Apelt, Frederic Venail, Olivier Scheidegger, Kathleen Seidel, Helene Rohrbach, Franck Forterre, Matthias S Dettmer, Inti Zlobec and 6 more

Open access · goldAbstract read
In one paragraph

Article in Frontiers in surgery, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors at 5 institutions in 3 countries.

Juan AnsóARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland.
Cilgia DürDepartment of Head and Neck Surgery, Inselspital, University of Bern, Bern, Switzerland.
Mareike ApeltARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland.
Frederic VenailDepartment of Otolaryngology-Head and Neck Surgery, University Hospital of Montpellier, Montpellier, France.
Olivier ScheideggerDepartment of Neurology, Inselspital, University of Bern, Bern, Switzerland.
Kathleen SeidelDepartment of Neurosurgery, Inselspital, University of Bern, Bern, Switzerland.
Helene RohrbachVetsuisse Faculty, Veterinary Hospital, University of Bern, Bern, Switzerland.
Franck ForterreVetsuisse Faculty, Veterinary Hospital, University of Bern, Bern, Switzerland.
Matthias S DettmerInstitute of Pathology, University of Bern, Bern, Switzerland.
Inti ZlobecInstitute of Pathology, University of Bern, Bern, Switzerland.
Klaus WeberAnaPath Services, Liestal, Switzerland.
Marco MatulicCAScination, Bern, Switzerland.
Masoud Zoka-AssadiMED-EL Medical Electronics, Innsbruck, Austria.
Markus HuthDepartment of Head and Neck Surgery, Inselspital, University of Bern, Bern, Switzerland.
Marco CaversaccioDepartment of Head and Neck Surgery, Inselspital, University of Bern, Bern, Switzerland.
Stefan WeberARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland.
University of Bern · CHUniversity Hospital of Bern · CHCentre Hospitalier Universitaire de Montpellier · FRMED-EL (Austria) · ATPsychiatry Baselland · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Facial nerve damage has a detrimental effect on a patient's life, therefore safety mechanisms to ensure its preservation are essential during lateral skull base surgery. During robotic cochlear implantation a trajectory passing the facial nerve at <0.5 mm is needed. Recently a stimulation probe and nerve monitoring approach were developed and introduced clinically, however for patient safety no trajectory was drilled closer than 0.4 mm. Here we assess the performance of the nerve monitoring system at closer distances. In a sheep model eight trajectories were drilled to test the setup followed by 12 trajectories during which the ENT surgeon relied solely on the nerve monitoring system and aborted the robotic drilling process if intraoperative nerve monitoring alerted of a distance <0.1 mm. Microcomputed tomography images and histopathology showed prospective use of the technology prevented facial nerve damage. Facial nerve monitoring integrated in a robotic system supports the surgeon's ability to proactively avoid damage to the facial nerve during robotic drilling in the mastoid.

Indexed as

monopolar and bipolarnerve stimulation electrodeneurophysiology monitoringrobotic cochlear implantationrobotic surgery

Identifiers

PMID31632981
PMCPMC6781655
OpenAlexW2978026216

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.