Evidence map›Paper›PMID 31631404›Full record

ArticleMagnetic resonance in medicine2020

Trabecular bone imaging using a 3D adiabatic inversion recovery prepared ultrashort TE Cones sequence at 3T.

Ya-Jun Ma, Yanjun Chen, Liang Li, Zhenyu Cai, Zhao Wei, Saeed Jerban, Hyungseok Jang, Eric Y Chang, Jiang Du

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed
4.1field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 47 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Bone Biomarkers Based on Magnetic Resonance Imaging.Seminars in musculoskeletal radiology · 2024
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Review
  16. Review
  17. Assessment of Osteoporosis in Lumbar Spine:Frontiers in endocrinology · 2022
    Article
  18. Review
  19. Article
  20. Brain ultrashort TJournal of magnetic resonance (San Diego, Calif. : 1997) · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Ya-Jun MaDepartment of Radiology, University of California, San Diego, California.ORCID 0000-0003-0830-9232
Yanjun ChenDepartment of Radiology, University of California, San Diego, California.
Liang LiDepartment of Radiology, University of California, San Diego, California.
Zhenyu CaiDepartment of Radiology, University of California, San Diego, California.
Zhao WeiDepartment of Radiology, University of California, San Diego, California.
Saeed JerbanDepartment of Radiology, University of California, San Diego, California.
Hyungseok JangDepartment of Radiology, University of California, San Diego, California.ORCID 0000-0002-3597-9525
Eric Y ChangDepartment of Radiology, University of California, San Diego, California.
Jiang DuDepartment of Radiology, University of California, San Diego, California.
University of California San Diego · US

Funding

Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of BoneR01AR068987 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DU, JIANG · 2015 to 2024
$4.9M
Quantitative UTE MR Imaging: Sensitive Biomarkers for OsteoarthritisR01AR062581 · NIAMS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DU, JIANG · 2013 to 2022
$4.1M
UTE Magnetic Resonance Imaging: New Biomarkers for Multiple SclerosisR01NS092650 · NINDS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DU, JIANG · 2015 to 2019
$1.9M
Ultrashort Echo Time Magnetic Resonance Imaging of Bone Stress InjuriesR21AR073496 · NIAMS · VETERANS MEDICAL RESEARCH FDN/SAN DIEGO · PI CHANG, ERIC Y · 2018 to 2019
$343k
Quantitative Magnetic Resonance Imaging of Human Rotator Cuff TendonI01CX001388 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHANG, ERIC Y · 2016 to 2024
–
Quantitative Measurement of Joint pH with Magnetic Resonance ImagingI01RX002604 · VA · VA SAN DIEGO HEALTHCARE SYSTEM · PI CHANG, ERIC Y · 2018 to 2022
–
CSRD VA I01 CX001388NIAMS NIH HHS R01 AR062581NIAMS NIH HHS R01 AR068987NIAMS NIH HHS R21 AR073496NINDS NIH HHS R01 NS092650RRD VA I01 RX002604
6 · The paper itself

Abstract

purposeTo investigate direct imaging of trabecular bone using a 3D adiabatic inversion recovery prepared ultrashort TE cones (3D IR-UTE-Cones) sequence.

methodsThe proposed 3D IR-UTE-Cones sequence used a broadband adiabatic inversion pulse together with a short TR/TI combination to suppress signals from long T

resultsNumeric simulation suggests that the IR technique with a short TR/TI combination provides sufficient suppression of long T

conclusionThe 3D IR-UTE-Cones sequence with a short TR/TI combination provides robust suppression of long T

Indexed as

Cancellous BoneMagnetic Resonance ImagingComputer SimulationHumansImaging, Three-DimensionalPhantoms, Imagingadiabatic inversion recoverytrabecular boneultrashort echo time

Identifiers

PMID31631404
PMCPMC6982597
OpenAlexW2981855390

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.