ArticleMagnetic resonance in medicine2020
Near-isotropic noncontrast MRA of the renal and peripheral arteries using a thin-slab stack-of-stars quiescent interval slice-selective acquisition.
Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Diagnostic performance of non-contrast quiescent-interval slice-selective (QISS) magnetic resonance angiography for evaluation of the renal arterial vasculature compared to computed tomography angiography (CTA) as reference standard.European journal of radiology open · 2025Article
- Simultaneous Luminal and Hemodynamic Evaluation of the Cervical Arteries Using Nonenhanced 3D Quantitative Quiescent-Interval Slice-Selective Magnetic Resonance Angiography.Journal of magnetic resonance imaging : JMRI · 2025Article
- Non-contrast preoperative MRI for determining renal perfusion and visualizing renal arteries in potential living kidney donors at 1.5 Tesla.Clinical kidney journal · 2024Article
- Quantitative time-of-flight MR angiography for simultaneous luminal and hemodynamic evaluation of the intracranial arteries.Magnetic resonance in medicine · 2022Article
- Comparison of 2D and 3D quiescent-interval slice-selective non-contrast MR angiography in patients with peripheral artery disease.Magma (New York, N.Y.) · 2021Article
- Super-resolution head and neck MRA using deep machine learning.Magnetic resonance in medicine · 2021Article
- "Push-button" noncontrast MR angiography using balanced TMagnetic resonance in medicine · 2021Article
- High spatial resolution whole-neck MR angiography using thin-slab stack-of-stars quiescent interval slice-selective acquisition.Magnetic resonance in medicine · 2020Article
- Radial-based acquisition strategies for pre-procedural non-contrast cardiovascular magnetic resonance angiography of the pulmonary veins.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeNoncontrast MRA avoids potential risks from gadolinium-based contrast agents. A 2D noncontrast technique, quiescent interval slice-selective (QISS), accurately evaluates the peripheral arteries but has limited spatial resolution along the slice direction. We therefore implemented a prototype thin-slab stack-of-stars version (tsSOS-QISS) with nearly isotropic spatial resolution and tested it in the renal and peripheral arteries of healthy subjects and patients with vascular disease.
methodsThe study was approved by the hospital institutional review board. A total of 16 subjects were scanned at 1.5 T: 7 for imaging of the renal arteries and 9 for imaging of the peripheral arteries. For tsSOS-QISS of the renal arteries, each slab consisted of about sixteen 1.3-mm-thick or 2.0-mm-thick slices (interpolated to thirty-two 0.65-mm-thick or 1.0-mm-thick 3D partitions) oriented in an oblique axial or oblique coronal view along the length of the target vessel and was acquired in a breath-hold. For tsSOS-QISS of the peripheral arteries, 20 axial overlapping thin slabs were typically acquired, each with twelve 1.3-mm-thick slices (interpolated to twenty-four 0.65-mm-thick 3D partitions). Image quality, vessel sharpness in multiplanar reconstructions, and normalized SNR were measured.
resultsImage quality and normalized SNR in the renal and peripheral arteries were significantly better compared with 2D QISS acquired at the same spatial resolution, while vessel sharpness was improved in multiplanar reconstructions of the renal arteries.
conclusionThe tsSOS-QISS technique overcomes a significant limitation of 2D QISS by providing nearly isotropic spatial resolution with improved image quality, normalized SNR, and vessel sharpness in multiplanar reconstructions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.