Evidence map›Paper›PMID 31630082›Full record

ArticleHearing research2019

Changes over time in the electrically evoked compound action potential (ECAP) interphase gap (IPG) effect following cochlear implantation in Guinea pigs.

Kara C Schvartz-Leyzac, Deborah J Colesa, Christopher J Buswinka, Donald L Swiderski, Yehoash Raphael, Bryan E Pfingst

Open access · greenAbstract read
In one paragraph

Article in Hearing research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Multicargo Porous Cochlear Electrode Coating for Antifibrosis After Cochlear Implantation.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  4. Article
  5. Article
  6. Article
  7. Cochlear Health and Cochlear-implant Function.Journal of the Association for Research in Otolaryngology : JARO · 2023
    Review
  8. Article
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Effects of Electrode Location on Estimates of Neural Health in Humans with Cochlear Implants.Journal of the Association for Research in Otolaryngology : JARO · 2020
    Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Kara C Schvartz-LeyzacKresge Hearing Research Institute, Department of Otolaryngology-Head and Neck Surgery, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, MI, 48109-5616, USA; Hearing Rehabilitation Center, Department of Otolaryngology-Head and Neck Surgery, University of Michigan, 475 W. Market Place, Building 1, Suite A, Ann Arbor, MI, 48108. Electronic address: kleyzac@med.umich.edu.
Deborah J ColesaKresge Hearing Research Institute, Department of Otolaryngology-Head and Neck Surgery, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, MI, 48109-5616, USA.
Christopher J BuswinkaKresge Hearing Research Institute, Department of Otolaryngology-Head and Neck Surgery, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, MI, 48109-5616, USA.
Donald L SwiderskiKresge Hearing Research Institute, Department of Otolaryngology-Head and Neck Surgery, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, MI, 48109-5616, USA.
Yehoash RaphaelKresge Hearing Research Institute, Department of Otolaryngology-Head and Neck Surgery, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, MI, 48109-5616, USA.
Bryan E PfingstKresge Hearing Research Institute, Department of Otolaryngology-Head and Neck Surgery, University of Michigan, 1150 West Medical Center Drive, Ann Arbor, MI, 48109-5616, USA.
University of Michigan–Ann Arbor · US

Funding

Scientific Synergy CoreP30DC005188 · NIDCD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI DOLAN, DAVID FRANCIS · 2002 to 2016
$10.3M
Functionally Important Features of the Electrically Stimulated CochleaR01DC015809 · NIDCD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI PFINGST, BRYAN E · 2017 to 2021
$3.2M
Across-Site Patterns of Perception with Cochlear ImplantsR01DC010786 · NIDCD · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI PFINGST, BRYAN E · 2010 to 2014
$1.6M
NIDCD NIH HHS P30 DC005188NIDCD NIH HHS R01 DC010786NIDCD NIH HHS R01 DC015809
6 · The paper itself

Abstract

The electrically-evoked compound action potential (ECAP) is correlated with spiral ganglion neuron (SGN) density in cochlear implanted animals. In a previous study, we showed that ECAP amplitude growth function (AGF) linear slopes for stimuli with a constant interphase gap (IPG) changed significantly over time following implantation. Related studies have also shown that 1) IPG sensitivity for ECAP measures ("IPG Effect") is related to SGN density in animals and 2) the ECAP IPG Effect is related to speech recognition performance in humans with cochlear implants. The current study examined how the ECAP IPG Effect changed following cochlear implantation in four non-deafened guinea pigs with residual inner hair cells (IHCs) and 5 deafened, neurotrophin-treated guinea pigs. Simple impedances were measured on the same days as the ECAP measures. Generally, non-deafened implanted animals with higher SGN survival demonstrated higher ECAP AGF linear slope and peak amplitude values than the deafened, implanted guinea pigs. The ECAP IPG Effect for the AGF slopes and peak amplitudes was also larger in the hearing animals. The N1 latencies for a constant IPG were not different between groups, but the N1 latency IPG Effect was smaller in the non-deafened, implanted animals. Similar to previously reported results, ECAP measures using a fixed or changing IPG required as many as three months after implantation before a stable point could be calculated, but this was dependent on the animal and condition. For all ECAP measures most animals showed greater variance in the first 30 days post-implantation. Post-implantation changes in ECAPs and impedances were not correlated with one another. Results from this study are helpful for estimating the mechanisms underlying ECAP characteristics and have implications for clinical application of the ECAP measures in long-term human cochlear implant recipients. Specifically, these measures could help to monitor neural health over a period of time, or during a time of stability these measures could be used to help select electrode sites for activation in clinical programming.

Indexed as

Cochlear ImplantsEvoked PotentialsAcoustic StimulationAnimalsCell DeathCochlear ImplantationDeafnessDisease Models, AnimalElectric StimulationGuinea PigsReaction TimeSpiral GanglionTime FactorsAuditory prosthesisCochlear implantECAPGuinea pigNeural health

Identifiers

PMID31630082
PMCPMC7093157
OpenAlexW2978212006

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.