ArticleJMIR mHealth and uHealth2019
Validation and Acceptability of a Cuffless Wrist-Worn Wearable Blood Pressure Monitoring Device Among Users and Health Care Professionals: Mixed Methods Study.
Article in JMIR mHealth and uHealth, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
26 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Non-invasive blood pressure monitoring using wearables for cardiovascular risk assessment: a systematic review.Archives of gynecology and obstetrics · 2026Pooled it
- Wearable Health Devices in Health Care: Narrative Systematic Review.JMIR mHealth and uHealth · 2020Pooled it
- Wearable, cuffless, and portable devices for blood pressure monitoring (2015-2025): a scoping review of technologies, calibration, clinical validation, and regulatory frameworks.Frontiers in digital health · 2026Article
- Comparing the accuracy of continuous blood pressure monitoring using wearable cuffless devices with conventional 24-hour ambulatory blood pressure monitoring: A systematic review and meta-analysis.American journal of preventive cardiology · 2025Article
- Feasibility of Wearable Digital Healthcare Devices Among Korean Male Seafarers: A Pilot Study.Healthcare (Basel, Switzerland) · 2025Article
- Article
- Feasibility of watch-based blood pressure monitoring device in daily blood pressure monitoring.Clinical hypertension · 2025Article
- Feasibility and Effectiveness of a Ring-Type Blood Pressure Measurement Device Compared With 24-Hour Ambulatory Blood Pressure Monitoring Device.Korean circulation journal · 2024Article
- The reality and serendipity of cuffless blood pressure monitoring.Hypertension research : official journal of the Japanese Society of Hypertension · 2023Article
- Design and development of a smartphone app for hypertension management: An intervention mapping approach.Frontiers in public health · 2023Review
- Advancement in the Cuffless and Noninvasive Measurement of Blood Pressure: A Review of the Literature and Open Challenges.Bioengineering (Basel, Switzerland) · 2022Review
- Review
- Smartphone Apps for Diabetes Medication Adherence: Systematic Review.JMIR diabetes · 2022Review
- Chinese adult segmentation according to health skills and analysis of their use for smart home: a cross-sectional national survey.BMC health services research · 2022Article
- Wearable cuffless blood pressure monitoring devices: a systematic review and meta-analysis.European heart journal. Digital health · 2022Review
- 2022 Guidelines of the Taiwan Society of Cardiology and the Taiwan Hypertension Society for the Management of Hypertension.Acta Cardiologica Sinica · 2022Article
- Consensus on Recommended Functions of a Smart Home System to Improve Self-Management Behaviors in People With Heart Failure: A Modified Delphi Approach.Frontiers in cardiovascular medicine · 2022Article
- Prediction of cardiac autonomic neuropathy using a machine learning model in patients with diabetes.Therapeutic advances in endocrinology and metabolism · 2022Article
- Smart wearable devices in cardiovascular care: where we are and how to move forward.Nature reviews. Cardiology · 2021Review
- Cardiovascular diseases risk prediction in patients with diabetes: Posthoc analysis from a matched case-control study in Bangladesh.Journal of diabetes and metabolic disorders · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundBlood pressure (BP) is an important modifiable cardiovascular risk factor, yet its long-term monitoring remains problematic. Wearable cuffless devices enable the capture of multiple BP measures during everyday activities and could improve BP monitoring, but little is known about their validity or acceptability.
objectiveThis study aimed to validate a wrist-worn cuffless wearable BP device (Model T2; TMART Technologies Limited) and assess its acceptability among users and health care professionals.
methodsA mixed methods study was conducted to examine the validity and comparability of a wearable cuffless BP device against ambulatory and home devices. BP was measured simultaneously over 24 hours using wearable and ambulatory devices and over 7 days using wearable and home devices. Pearson correlation coefficients compared the degree of association between the measures, and limits of agreement (LOA; Bland-Altman plots) were generated to assess measurement bias. Semistructured interviews were conducted with users and 10 health care professionals to assess acceptability, facilitators, and barriers to using the wearable device. Interviews were audio recorded, transcribed, and analyzed.
resultsA total of 9090 BP measurements were collected from 20 healthy volunteers (mean 20.3 years, SD 5.4; N=10 females). Mean (SD) systolic BP (SBP)/diastolic BP (DBP) measured using the ambulatory (24 hours), home (7 days), and wearable (7 days) devices were 126 (SD 10)/75 (SD 6) mm Hg, 112 (SD 10)/71 (SD 9) mm Hg and 125 (SD 4)/77 (SD 3) mm Hg, respectively. Mean (LOA) biases and precision between the wearable and ambulatory devices over 24 hours were 0.5 (-10.1 to 11.1) mm Hg for SBP and 2.24 (-17.6 to 13.1) mm Hg for DBP. The mean biases (LOA) and precision between the wearable and home device over 7 days were -12.7 (-28.7 to 3.4) mm Hg for SBP and -5.6 (-20.5 to 9.2) mm Hg for DBP. The wearable BP device was well accepted by participants who found the device easy to wear and use. Both participants and health care providers agreed that the wearable cuffless devices were easy to use and that they could be used to improve BP monitoring.
conclusionsWearable BP measures compared well against a gold-standard ambulatory device, indicating potential for this user-friendly method to augment BP management, particularly by enabling long-term monitoring that could improve treatment titration and increase understanding of users' BP response during daily activity and stressors.