ReviewThe Cochrane database of systematic reviews2019
Mechanical methods for induction of labour.
Review in The Cochrane database of systematic reviews, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 39 papers, 7 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Effectiveness and Safety of Double-balloon Versus Vaginal Prostaglandin for Cervical Ripening in Women With Low-risk Pregnancies: A Randomized Controlled Trial (DOBA-PRO)
Comparing Two Methods for Inserting a Balloon Catheter : View-guided Approach Using a Speculum Versus Manual Guided Approach at Cervical Examination - a Prospective Randomized Trail
The Effect of Nipple Stimulation Combined With Foley Balloon Catheter on Bishop Score and Induction-to-delivery Interval: a Prospective Randomized Trial
Who cites it
39 citing papers in PubMed, 7 syntheses or guidelines pooled it.
- Balloon catheter plus concurrent vaginal misoprostol versus vaginal misoprostol alone for cervical ripening in induction of labor: A systematic review and an individual participant data meta-analysis of randomized controlled trials.International journal of gynaecology and obstetrics: the official organ of the International Federation of Gynaecology and Obstetrics · 2026Pooled it
- Outpatient or Inpatient Setting for Cervical Ripening Before Induction of Labour: An Individual Participant Data Meta-Analysis.BJOG : an international journal of obstetrics and gynaecology · 2025Pooled it
- Double-vs single-balloon catheter for induction of labor: Systematic review and individual participant data meta-analysis.Acta obstetricia et gynecologica Scandinavica · 2023Pooled it
- Quality appraisal of systematic reviews on methods of labour induction: a systematic review.Archives of gynecology and obstetrics · 2021Pooled it
- Intracervical Foley Catheter Plus Intravaginal Misoprostol vs Intravaginal Misoprostol Alone for Cervical Ripening: A Meta-Analysis.International journal of environmental research and public health · 2020Pooled it
- Membrane sweeping for induction of labour.The Cochrane database of systematic reviews · 2020Pooled it
- A Comparison of Synthetic Osmotic Dilators and Pharmacologic Agents for Cervical Ripening in Induction of Labor: A Systematic Review and Meta-Analysis.Journal of midwifery & women's healthPooled it
- Introducing the participant-generated experience and satisfaction (PaGES) index: a novel, longitudinal mixed-methods evaluation tool.BMC medical research methodology · 2023Trial
- Induction of labor with Foley catheter and risk of subsequent preterm birth: follow-up study of two randomized controlled trials (PROBAAT-1 and -2).Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology · 2021Trial
- Cervical ripening in prolonged pregnancies by silicone double balloon catheter versus vaginal dinoprostone slow release system: The MAGPOP randomised controlled trial.PLoS medicine · 2021Trial
- Article
- Prostaglandins versus transcervical balloon for induction of labor for fetal growth restriction: study protocol for a randomized, multicenter, open-label, superiority trial (PROBIN).BMC pregnancy and childbirth · 2026Article
- Intrapartum posterior cul-de-sac rupture, a clinical enigma: a case report.International journal of surgery case reports · 2026Article
- Article
- Investigating the impact of trial retractions on the healthcare evidence ecosystem (VITALITY Study I): retrospective cohort study.BMJ (Clinical research ed.) · 2025Article
- Effectiveness and Safety of the Double Intracervical Balloon vs Dinoprostone in Patients with Previous Cesarean Section.Reproductive sciences (Thousand Oaks, Calif.) · 2024Observational
- Outpatient elective induction of labour at 39 weeks' gestation (HOME INDUCTION): an open-label, randomised, controlled, phase III, non-inferiority trial.EClinicalMedicine · 2024Article
- Efficacy and safety of double balloon catheter and dinoprostone for labor induction in multipara at term.Archives of gynecology and obstetrics · 2024Article
- Time from insertion to expulsion of cervical ripening balloon in preterm versus term inductions of labor.Archives of gynecology and obstetrics · 2024Article
- The infection, cervical and perineal lacerations in relation to postpartum hemorrhage following vaginal delivery induced by Cook balloon catheter.Archives of gynecology and obstetrics · 2024Article
Corrections and comments
- Updated by
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMechanical methods were the first methods developed to ripen the cervix and induce labour. During recent decades they have been substituted by pharmacological methods. Potential advantages of mechanical methods, compared with pharmacological methods may include reduction in side effects that could improve neonatal outcomes. This is an update of a review first published in 2001, last updated in 2012.
objectivesTo determine the effectiveness and safety of mechanical methods for third trimester (> 24 weeks' gestation) induction of labour in comparison with prostaglandin E2 (PGE2) (vaginal and intracervical), low-dose misoprostol (oral and vaginal), amniotomy or oxytocin. SEARCH
methodsFor this update, we searched Cochrane Pregnancy and Childbirth's Trials Register, ClinicalTrials.gov, the WHO International Clinical Trials Registry Platform (ICTRP), and reference lists of retrieved studies (9 January 2018). We updated the search in March 2019 and added the search results to the awaiting classification section of the review. SELECTION CRITERIA: Clinical trials comparing mechanical methods used for third trimester cervical ripening or labour induction with pharmacological methods.Mechanical methods include: (1) the introduction of a catheter through the cervix into the extra-amniotic space with balloon insufflation; (2) introduction of laminaria tents, or their synthetic equivalent (Dilapan), into the cervical canal; (3) use of a catheter to inject fluid into the extra-amniotic space (EASI).This review includes the following comparisons: (1) specific mechanical methods (balloon catheter, laminaria tents or EASI) compared with prostaglandins (different types, different routes) or with oxytocin; (2) single balloon compared to a double balloon; (3) addition of prostaglandins or oxytocin to mechanical methods compared with prostaglandins or oxytocin alone. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trials for inclusion and assessed risk of bias. Two review authors independently extracted data and assessed the quality of the evidence using the GRADE approach. MAIN
resultsThis review update includes a total of 113 trials (22,373 women) contributing data to 21 comparisons. Risk of bias of trials varied. Overall, the evidence was graded from very-low to moderate quality. All evidence was downgraded for lack of blinding and, for many comparisons, the effect estimates were too imprecise to make a valid judgement.Balloon versus vaginal PGE2: there may be little or no difference in vaginal deliveries not achieved within 24 hours (average risk ratio (RR) 1.01, 95% confidence interval (CI) 0.82 to 1.26; 7 studies; 1685 women; I² = 79%; low-quality evidence) and there probably is little or no difference in caesarean sections (RR 1.00, 95% CI 0.92 to 1.09; 28 studies; 6619 women; moderate-quality evidence) between induction of labour with a balloon catheter and vaginal PGE2. A balloon catheter probably reduces the risk of uterine hyperstimulation with fetal heart rate (FHR) changes (RR 0.35, 95% CI 0.18 to 0.67; 6 studies; 1966 women; moderate-quality evidence), serious neonatal morbidity or perinatal death (RR 0.48, 95% CI 0.25 to 0.93; 8 studies; 2757 women; moderate-quality evidence) and may slightly reduce the risk of aneonatal intensive care unit (NICU) admission (RR 0.82, 95% CI 0.65 to 1.04; 3647 women; 12 studies; low-quality evidence). It is uncertain whether there is a difference in serious maternal morbidity or death (RR 0.20, 95% CI 0.01 to 4.12; 4 studies; 1481 women) or five-minute Apgar score < 7 (RR 0.74, 95% CI 0.49 to 1.14; 4271 women; 14 studies) because the quality of the evidence was found to be very low and low, respectively.Balloon versus low-dose vaginal misoprostol: it is uncertain whether there is a difference in vaginal deliveries not achieved within 24 hours between induction of labour with a balloon catheter and vaginal misoprostol (RR 1.09, 95% CI 0.85 to 1.39; 340 women; 2 studies; low-quality evidence). A balloon catheter probably reduces the risk of uterine hyperstimulation with FHR changes (RR 0.39, 95% CI 0.18 to 0.85; 1322 women; 8 studies; moderate-quality evidence) but may increase the risk of a caesarean section (average RR 1.28, 95% CI 1.02 to 1.60; 1756 women; 12 studies; I² = 45%; low-quality evidence). It is uncertain whether there is a difference in serious neonatal morbidity or perinatal death (RR 0.58, 95% CI 0.12 to 2.66; 381 women; 3 studies), serious maternal morbidity or death (no events; 4 studies, 464 women), both very low-quality evidence, and five-minute Apgar score < 7 (RR 1.00, 95% CI 0.50 to 1.97; 941 women; 7 studies) and NICU admissions (RR 1.00, 95% CI 0.61 to 1.63; 1302 women; 9 studies) both low-quality evidence.Balloon versus low-dose oral misoprostol: a balloon catheter probably increases the risk of a vaginal delivery not achieved within 24 hours (RR 1.28, 95% CI 1.13 to 1.46; 782 women, 2 studies, and probably slightly increases the risk of a caesarean section (RR 1.17, 95% CI 1.04 to 1.32; 3178 women; 7 studies; both moderate-quality evidence) when compared to oral misoprostol. It is uncertain whether there is a difference in uterine hyperstimulation with FHR changes (RR 0.81, 95% CI 0.48 to 1.38; 2033 women; 2 studies), serious neonatal morbidity or perinatal death (RR 1.11, 95% CI 0.60 to 2.06; 2627 women; 3 studies), both low-quality evidence, serious maternal morbidity or death (RR 0.50, 95% CI 0.05 to 5.52; 2627 women; 3 studies), very low-quality evidence, five-minute Apgar scores < 7 (RR 0.71, 95% CI 0.38 to 1.32; 2693 women; 4 studies) and NICU admissions (RR 0.82, 95% CI 0.58 to 1.17; 2873 women; 5 studies) both low-quality evidence. AUTHORS'
conclusionsLow- to moderate-quality evidence shows mechanical induction with a balloon is probably as effective as induction of labour with vaginal PGE2. However, a balloon seems to have a more favourable safety profile. More research on this comparison does not seem warranted.Moderate-quality evidence shows a balloon catheter may be slightly less effective as oral misoprostol, but it remains unclear if there is a difference in safety outcomes for the neonate. When compared to low-dose vaginal misoprostol, low-quality evidence shows a balloon may be less effective, but probably has a better safety profile.Future research could be focused more on safety aspects for the neonate and maternal satisfaction.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.