Evidence map›Paper›PMID 31620547›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2019

Resolution characterization of a silicon-based, photon-counting computed tomography prototype capable of patient scanning.

Joakim da Silva, Fredrik Grönberg, Björn Cederström, Mats Persson, Martin Sjölin, Zlatan Alagic, Robert Bujila, Mats Danielsson

Open access · bronzeAbstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 53 citations in OpenAlex.

  1. Article
  2. Article
  3. Guidelines for the Selection of Scintillators for Indirect Photon-Counting X-ray Detectors.Chemistry of materials : a publication of the American Chemical Society · 2025
    Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. 1-μm spatial resolution in silicon photon-counting CT detectors.Journal of medical imaging (Bellingham, Wash.) · 2021
    Article
  14. Article
  15. Computed tomography recent history and future perspectives.Journal of medical imaging (Bellingham, Wash.) · 2021
    Review
  16. Photon Counting CT: Clinical Applications and Future Developments.IEEE transactions on radiation and plasma medical sciences · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Joakim da SilvaKTH Royal Institute of Technology, Department of Physics, Stockholm, Sweden.ORCID https://orcid.org/0000-0002-7771-842X
Fredrik GrönbergKTH Royal Institute of Technology, Department of Physics, Stockholm, Sweden.
Björn CederströmPrismatic Sensors AB, Stockholm, Sweden.
Mats PerssonStanford University, Department of Bioengineering, Stanford, California, United States.ORCID https://orcid.org/0000-0002-5092-8822
Martin SjölinPrismatic Sensors AB, Stockholm, Sweden.
Zlatan AlagicKarolinska University Hospital, Functional Unit for Trauma and Musculoskeletal Radiology, Stockholm, Sweden.
Robert BujilaKTH Royal Institute of Technology, Department of Physics, Stockholm, Sweden.
Mats DanielssonKTH Royal Institute of Technology, Department of Physics, Stockholm, Sweden.
KTH Royal Institute of Technology · SESensors (United States) · USKarolinska Institutet · SEKarolinska University Hospital · SEStanford University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Photon-counting detectors are expected to bring a range of improvements to patient imaging with x-ray computed tomography (CT). One is higher spatial resolution. We demonstrate the resolution obtained using a commercial CT scanner where the original energy-integrating detector has been replaced by a single-slice, silicon-based, photon-counting detector. This prototype constitutes the first full-field-of-view silicon-based CT scanner capable of patient scanning. First, the pixel response function and focal spot profile are measured and, combining the two, the system modulation transfer function is calculated. Second, the prototype is used to scan a resolution phantom and a skull phantom. The resolution images are compared to images from a state-of-the-art CT scanner. The comparison shows that for the prototype

Indexed as

computed tomographyphoton-countingresolutionsilicon

Identifiers

PMID31620547
PMCPMC6792007
OpenAlexW2980863948

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.