Evidence map›Paper›PMID 31619232›Full record

ArticleBMC veterinary research2019

Ultrasonographic assessment of normal jugular veins in Standardbred horses.

Maria Pia Pasolini, Giuseppe Spinella, Chiara Del Prete, Simona Valentini, Pierpaolo Coluccia, Luigi Auletta, Michele Greco, Leonardo Meomartino

Abstract read
In one paragraph

Article in BMC veterinary research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Ultrasonographic Measurement of Kidney-to-Aorta Parameters in French Bulldogs.Veterinary radiology & ultrasound : the official journal of the American College of Veterinary Radiology and the International Veterinary Radiology Association · 2026
    Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Maria Pia PasoliniDepartment of Veterinary Medicine and Animal Production, University of Naples Federico II, Via a Federico Delpino, 1, 80137, Naples, Italy.
Giuseppe SpinellaDepartment of Veterinary Medical Sciences, University Alma Mater of Bologna, via Tolara di Sopra 50, 40064, Ozzano dell'Emilia, BO, Italy.
Chiara Del PreteDepartment of Veterinary Medicine and Animal Production, University of Naples Federico II, Via a Federico Delpino, 1, 80137, Naples, Italy. chiara.delprete@unina.it.ORCID http://orcid.org/0000-0002-2603-8598
Simona ValentiniDepartment of Veterinary Medical Sciences, University Alma Mater of Bologna, via Tolara di Sopra 50, 40064, Ozzano dell'Emilia, BO, Italy.
Pierpaolo ColucciaDepartment of Veterinary Medicine and Animal Production, University of Naples Federico II, Via a Federico Delpino, 1, 80137, Naples, Italy.
Luigi AulettaIRCCS SDN, via E. Gianturco 113, 80143, Naples, Italy.
Michele GrecoClevedale Veterinary Practice, Home Farm, Redcar, UK.
Leonardo MeomartinoInterdepartmental Radiology Centre, University of Naples Federico II, Via Federico Delpino 1, 80137, Naples, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundUltrasonography (US) is the recommended imaging technique to evaluate jugular veins. This prospective randomized clinical study was designed to collect a series of B-mode US measurements of manually distended jugular veins in healthy Italian Standardbreds and to find possible correlations between ultrasound measurements and animal morphometric characteristics. Forty-two horses, eight males and 34 females (range 3-22 years; bodyweight 494.4 ± 41.7 kg), were included in the study. The diameters and wall thicknesses of both jugular veins were measured at three different sites of the neck. The differences in ultrasound measurements based on scans, age, gender, side, and site of the neck were evaluated by ANOVA or by the Kruskal-Wallis test. The effects of the morphometric measures on each ultrasound parameter were evaluated by MANOVA (P < 0.05).

resultsThe ultrasound measurements did not differ significantly between the three different sites or between genders; hence, they were pooled together in the results. On the transverse scan, the mean dorsoventral and lateromedial diameters were 1.58 ± 0.23 and 2.20 ± 0.25 cm, respectively; the mean superficial and deep wall thicknesses (SWT and DWT) were 0.07 ± 0.01 and 0.08 ± 0.01 cm, respectively. On the longitudinal scan, the mean dorsoventral diameter was 1.59 ± 0.26 cm, and the SWT and DWT were both 0.08 ± 0.01 cm. Neck length, from the caudal edge of the mandible to the thoracic inlet, was related to the dorsoventral diameter in both longitudinal and transverse scan and to the SWT and DWT in transverse scan, whereas height at the withers (measured with tape) and estimated weight were related to the wall thickness. Dividing the subjects into groups by age in years ("young" 3-7, "mature" 8-14, "old" > 14), differences were found for the lateromedial diameter in the transverse scan and the SWT on the longitudinal scan. The main limitation of this study was that only one operator performed the measurements.

conclusionThe US measurements of the jugular veins and their relationship with morphometric measures reported in this manuscript might be considered as guidelines both for early diagnosis and monitoring jugular vein abnormalities in healthy Italian Standardbred horses.

Indexed as

Age FactorsAnimalsFemaleHorsesJugular VeinsMaleProspective StudiesUltrasonographyEquineItalian StandardbredJugular veinsPhlebitisUltrasonographyVenous wall thickness

Identifiers

PMID31619232
PMCPMC6794831

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.