Evidence map›Paper›PMID 31618708›Full record

ArticlePhysics in medicine and biology2019

Design and evaluation of gapless curved scintillator arrays for simultaneous high-resolution and high-sensitivity brain PET.

Junwei Du, Xiaowei Bai, Chih-Chieh Liu, Jinyi Qi, Simon R Cherry

Open access · greenAbstract read
In one paragraph

Article in Physics in medicine and biology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Development of Whole-Body TOF-DOI PET Detector Using Dual-Ended Readout Method.IEEE transactions on instrumentation and measurement · 2025
    Article
  5. PET Detectors Based on Multi-Resolution SiPM Arrays.IEEE transactions on radiation and plasma medical sciences · 2024
    Article
  6. Article
  7. Review
  8. Performance of Dual-Ended Readout PET Detectors Based on BGO Arrays and BaSOIEEE transactions on radiation and plasma medical sciences · 2022
    Article
  9. Evaluation of advanced methods and materials for construction of scintillation detector light guides.Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine · 2022
    Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Junwei DuDepartment of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.ORCID 0000-0002-1719-8266
Xiaowei BaiDepartment of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.
Chih-Chieh LiuDepartment of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.
Jinyi QiDepartment of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.
Simon R CherryDepartment of Biomedical Engineering, University of California-Davis, One Shields Avenue, Davis, CA 95616, United States of America.
University of California, Davis · US

Funding

Innovative Silicon Photomultiplier Technologies for Small-Animal PETR01EB019439 · NIBIB · UNIVERSITY OF CALIFORNIA AT DAVIS · PI CHERRY, SIMON R · 2015 to 2018
$1.4M
NIBIB NIH HHS R01 EB019439
6 · The paper itself

Abstract

Brain PET scanners that simultaneously provide high-resolution across the field-of-view and high-sensitivity can be constructed using detectors based on SiPM arrays coupled to both ends of scintillator arrays with finely segmented and long detector elements. To reduce the dead space between detector modules and hence improve the sensitivity of PET scanners, crystal arrays with curved surfaces are proposed. In this paper, the performance of a proof-of-concept detector module with nine detector submodules based on SiPMs coupled to both ends of a curved LYSO array with a pitch size of 1.0  ×  1.0 mm

Indexed as

BrainElectronicsEquipment DesignHumansNormal DistributionPositron-Emission TomographyReference ValuesReproducibility of ResultsScintillation CountingSignal Processing, Computer-AssistedTemperature

Identifiers

PMID31618708
PMCPMC7485540
OpenAlexW2981263173

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.