ArticleNeurocritical care2020
Diagnostic Reliability of Headset-Type Continuous Video EEG Monitoring for Detection of ICU Patterns and NCSE in Patients with Altered Mental Status with Unknown Etiology.
Article in Neurocritical care, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Noninvasive mobile EEG as a tool for seizure monitoring and management: A systematic review.Epilepsia · 2022Pooled it
- Point-of-Care Electroencephalography in Acute Neurological Care: A Narrative Review.Neurology international · 2025Review
- Article
- Evaluation of a new wireless technique for continuous electroencephalography monitoring in neurological intensive care patients.Journal of clinical monitoring and computing · 2021Article
- Seizure Management in the Intensive Care Unit.Current treatment options in neurology · 2021Review
- Continuous EEG monitoring by a new simplified wireless headset in intensive care unit.BMC anesthesiology · 2020Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND/
objectiveSimplified continuous electroencephalogram (cEEG) monitoring has shown improvement in detecting seizures; however, it is insufficient in detecting abnormal EEG patterns, such as periodic discharges (PDs), rhythmic delta activity (RDA), spikes and waves (SW), and continuous slow wave (CS), as well as nonconvulsive status epilepticus (NCSE). Headset-type continuous video EEG monitoring (HS-cv EEG monitoring; AE-120A EEG Headset™, Nihon Kohden, Tokyo, Japan) is a recently developed easy-to-use technology with eight channels. However, its ability to detect abnormal EEG patterns with raw EEG data has not been comprehensively evaluated. We aimed to examine the diagnostic accuracy of HS-cv EEG monitoring in detecting abnormal EEG patterns and NCSE in patients with altered mental status (AMS) with unknown etiology. We also evaluated the time required to initiate HS-cv EEG monitoring in these patients.
methodsWe prospectively observed and retrospectively examined patients who were admitted with AMS between January and December 2017 at the neurointensive care unit at Asakadai Central General Hospital, Saitama, Japan. We excluded patients whose data were missing for various reasons, such as difficulties in recording, and those whose consciousness had recovered between HS-cv EEG and conventional cEEG (C-cEEG) monitoring. For the included patients, we performed HS-cv EEG monitoring followed by C-cEEG monitoring. Definitive diagnosis was confirmed by C-cEEG monitoring with the international 10-20 system. As the primary outcome, we verified the sensitivity and specificity of HS-cv EEG monitoring in detecting abnormal EEG patterns including PDs, RDA, SW, and CS, in detecting the presence of PDs, and in detecting NCSE. As the secondary outcome, we calculated the time to initiate HS-cv EEG monitoring after making the decision.
resultsFifty patients (76.9%) were included in the final analyses. The median age was 72 years, and 66% of the patients were male. The sensitivity and specificity of HS-cv EEG monitoring for detecting abnormal EEG patterns were 0.974 (0.865-0.999) and 0.909 (0.587-0.998), respectively, and for detecting PDs were 0.824 (0.566-0.926) and 0.970 (0.842-0.999), respectively. We diagnosed 13 (26%) patients with NCSE using HS-cv EEG monitoring and could detect NCSE with a sensitivity and specificity of 0.706 (0.440-0.897) and 0.970 (0.842-0.999), respectively. The median time needed to initiate HS-cv EEG was 57 min (5-142).
conclusionsHS-cv EEG monitoring is highly reliable in detecting abnormal EEG patterns, with moderate reliability for PDs and NCSE, and rapidly initiates cEEG monitoring in patients with AMS with unknown etiology.
Indexed as
Identifiers
31617115What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.