Evidence map›Paper›PMID 31614859›Full record

ArticleSensors (Basel, Switzerland)2019

Textile-Friendly Interconnection between Wearable Measurement Instrumentation and Sensorized Garments-Initial Performance Evaluation for Electrocardiogram Recordings.

Fernando Seoane, Azadeh Soroudi, Ke Lu, David Nilsson, Marie Nilsson, Farhad Abtahi, Mikael Skrifvars

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Advances in Printed Electronic Textiles.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Review
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Fernando SeoaneSwedish School of Textiles, University of Borås, 501 90 Borås, Sweden. fernando.seoane@hb.se.ORCID 0000-0002-6995-967X
Azadeh SoroudiSwedish School of Textiles, University of Borås, 501 90 Borås, Sweden. azadeh.soroudi@hb.se.ORCID 0000-0003-1044-5129
Ke LuDepartment of Electrical Engineering, Chalmers University of Technology, 412 96 Göteborg, Sweden. ke.lu@chalmers.se.ORCID 0000-0002-3256-9029
David NilssonRISE Research Institutes of Sweden, Box 857, 501 15 Borås, Sweden. david.nilsson@ri.se.
Marie NilssonRISE Research Institutes of Sweden, Box 857, 501 15 Borås, Sweden. marie.nilsson@ri.se.ORCID 0000-0003-2211-5661
Farhad AbtahiInstitute for Clinical Science, Intervention and Technology, Karolinska Institutet, 141 57 Huddinge, Sweden. farhad.abtahi@ki.se.ORCID 0000-0001-7807-8682
Mikael SkrifvarsSwedish School of Textiles, University of Borås, 501 90 Borås, Sweden. mikael.skrifvars@hb.se.ORCID 0000-0002-6596-8069
RISE Research Institutes of Sweden · SEUniversity of Borås · SEChalmers University of Technology · SEKarolinska Institutet · SEKarolinska University Hospital · SE

Funding

VINNOVA 2014-03413
6 · The paper itself

Abstract

The interconnection between hard electronics and soft textiles remains a noteworthy challenge in regard to the mass production of textile-electronic integrated products such as sensorized garments. The current solutions for this challenge usually have problems with size, flexibility, cost, or complexity of assembly. In this paper, we present a solution with a stretchable and conductive carbon nanotube (CNT)-based paste for screen printing on a textile substrate to produce interconnectors between electronic instrumentation and a sensorized garment. The prototype connectors were evaluated via electrocardiogram (ECG) recordings using a sensorized textile with integrated textile electrodes. The ECG recordings obtained using the connectors were evaluated for signal quality and heart rate detection performance in comparison to ECG recordings obtained with standard pre-gelled Ag/AgCl electrodes and direct cable connection to the ECG amplifier. The results suggest that the ECG recordings obtained with the CNT paste connector are of equivalent quality to those recorded using a silver paste connector or a direct cable and are suitable for the purpose of heart rate detection.

Indexed as

ElectrocardiographyTextilesWearable Electronic DevicesElectric ImpedanceHumansNanotubes, CarbonRegression AnalysisSurface PropertiesNanotubes, Carbonconductive polymerssmart textilestextile–electronic integrationwearable technology

Identifiers

PMID31614859
PMCPMC6832295
OpenAlexW2979780256

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.