ArticleJournal of applied clinical medical physics2019

Two-dimensional solid-state array detectors: A technique for in vivo dose verification in a variable effective area.

Kananan Utitsarn, Giordano Biasi, Nauljun Stansook, Ziyad A Alrowaili, Marco Petasecca, Martin Carolan, Vladimir L Perevertaylo, Wolfgang A Tomé, Tomas Kron, Michael L F Lerch and 1 more

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.6field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 4 countries.

Kananan UtitsarnCentre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW, Australia.
Giordano BiasiCentre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW, Australia.
Nauljun StansookCentre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW, Australia.
Ziyad A AlrowailiCentre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW, Australia.
Marco PetaseccaCentre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW, Australia.
Martin CarolanIllawarra Cancer Care Centre (ICCC), Wollongong Hospital, Wollongong, NSW, Australia.
Vladimir L PerevertayloSPA-BIT, Kiev, Ukraine.
Wolfgang A ToméDepartment of Radiation Oncology, Albert Einstein College of Medicine, New York City, NY, USA.
Tomas KronCentre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW, Australia.
Michael L F LerchCentre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW, Australia.
Anatoly B RosenfeldCentre for Medical Radiation Physics (CMRP), University of Wollongong, Wollongong, NSW, Australia.
University of Wollongong · AUAlbert Einstein College of Medicine · USCancer Hospital Lopburi · THUniversity of Melbourne · AUWollongong Hospital · AU

Funding

Gross FoundationLopburi Cancer HospitalNational Health and Medical Research Council of Australia APP1030159
6 · The paper itself

Abstract

purposeWe introduce a technique that employs a 2D detector in transmission mode (TM) to verify dose maps at a depth of d

methodsWe considered the detector prototype "MP512" (an array of 512 diode-sensitive volumes, 2 mm spatial resolution). Measurements in transmission mode were taken at SDDs in the range from 0.3 to 24 cm. Dose mode (DM) measurements were made at d

resultsIn the square fields, calculations agreed with measurements to within ±2.36%. In the IMRT fields, using acceptance criteria of 3%/3 mm, 2%/2 mm, 1%/1 mm, calculations had respective gamma passing rates greater than 96.89%, 90.50%, 62.20% (for a 4 cm SSD); and greater than 97.22%, 93.80%, 59.00% (for a 24 cm SSD). Lower rates (1%/1 mm criterion) can be explained by submillimeter misalignments, dose averaging in calculations, noise artifacts in film dosimetry.

conclusionsIt is possible to perform TM measurements at the SSD which produces the best fit between the area at d

Indexed as

AlgorithmsPhantoms, ImagingFilm DosimetryHumansOrgans at RiskRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-Assisted2D solid-state array detectorin vivo QAMP512transmission detector

Identifiers

PMID31609090
PMCPMC6839376
OpenAlexW2980049698

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.