ArticleIEEE transactions on microwave theory and techniques2019
Reducing RF-induced Heating near Implanted Leads through High-Dielectric Capacitive Bleeding of Current (CBLOC).
Article in IEEE transactions on microwave theory and techniques, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed.
- Reduction of radiofrequency induced implant heating via flexible metasurface shielding at 7 T.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2025Article
- Improving Image Quality and Decreasing SAR With High Dielectric Constant Pads in 3 T Fetal MRI.Journal of magnetic resonance imaging : JMRI · 2025Article
- A deep brain stimulation-conditioned RF coil for 3T MRI.Magnetic resonance in medicine · 2025Article
- Effect of surgical modification of deep brain stimulation lead trajectories on radiofrequency heating during MRI at 3T: from phantom experiments to clinical implementation.Journal of neurosurgery · 2024Article
- Brain-implanted conductors amplify radiofrequency fields in rodents: Advantages and risks.Bioelectromagnetics · 2024Article
- Modifying the trajectory of epicardial leads can substantially reduce MRI-induced RF heating in pediatric patients with a cardiac implantable electronic device at 1.5T.Magnetic resonance in medicine · 2023Article
- A new method to improve RF safety of implantable medical devices using inductive coupling at 3.0 T MRI.Magma (New York, N.Y.) · 2023Article
- Implants talk to each-other: RF heating changes when two DBS leads are present simultaneously during MRI.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023Article
- Low-field MRI's Spark on Implant Safety: A Closer Look at Radiofrequency Heating.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023Article
- Optimizing the trajectory of deep brain stimulation leads reduces RF heating during MRI at 3 T: Characteristics and clinical translation.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023Article
- Rapid prediction of MRI-induced RF heating of active implantable medical devices using machine learning.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2023Article
- Application of Machine learning to predict RF heating of cardiac leads during magnetic resonance imaging at 1.5 T and 3 T: A simulation study.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2023Article
- Article
- A comparative study of RF heating of deep brain stimulation devices in vertical vs. horizontal MRI systems.PloS one · 2022Article
- Predicting RF Heating of Conductive Leads During Magnetic Resonance Imaging at 1.5 T: A Machine Learning ApproachAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2021Article
- Machine learning-based prediction of MRI-induced power absorption in the tissue in patients with simplified deep brain stimulation lead models.IEEE transactions on electromagnetic compatibility · 2021Article
- Vertical open-bore MRI scanners generate significantly less radiofrequency heating around implanted leads: A study of deep brain stimulation implants in 1.2T OASIS scanners versus 1.5T horizontal systems.Magnetic resonance in medicine · 2021Article
- Silicon Carbide and MRI: Towards Developing a MRI Safe Neural Interface.Micromachines · 2021Article
- Patient's body composition can significantly affect RF power deposition in the tissue around DBS implants: ramifications for lead management strategies and MRI field-shaping techniques.Physics in medicine and biology · 2021Article
- Safety and image quality at 7T MRI for deep brain stimulation systems: Ex vivo study with lead-only and full-systems.PloS one · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Patients with implanted medical devices such as deep brain stimulation or spinal cord stimulation are often unable to receive magnetic resonance imaging (MRI). This is because once the device is within the radiofrequency (RF) field of the MRI scanner, electrically conductive leads act as antenna, amplifying the RF energy deposition in the tissue and causing possible excessive tissue heating. Here we propose a novel concept in lead design in which 40cm lead wires are coated with a ~1.2mm layer of high dielectric constant material (155 <
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.