Evidence map›Paper›PMID 31607445›Full record

ArticleJournal of chromatography. A2020

Ultrahigh-Performance capillary liquid chromatography-mass spectrometry at 35 kpsi for separation of lipids.

Matthew J Sorensen, Kelsey E Miller, James W Jorgenson, Robert T Kennedy

Abstract readEvaluation Study
In one paragraph

Article in Journal of chromatography. A, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Nano-liquid chromatography-mass spectrometry and recent applications in omics investigations.Analytical methods : advancing methods and applications · 2020
    Review
  10. Liquid chromatography above 20,000 PSI.Trends in analytical chemistry : TRAC · 2020
    Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Matthew J SorensenDepartment of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA.
Kelsey E MillerDepartment of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
James W JorgensonDepartment of Chemistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
Robert T KennedyDepartment of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA; Department of Pharmacology, University of Michigan, Ann Arbor, MI 48109, USA. Electronic address: rtkenn@umich.edu.

Funding

Regional Pilot And Feasibility Study Grants ProgramP30DK020572 · NIDDK · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Mehboob A Hussain · 2013 to 2026
$24.3M
High Resolution MetabolomicsR01DK101473 · NIDDK · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI KENNEDY, ROBERT T · 2015 to 2018
$1000k
NIDDK NIH HHS P30 DK020572NIDDK NIH HHS R01 DK101473
6 · The paper itself

Abstract

Improvements in sample preparation, separation, and mass spectrometry continue to expand the coverage in LC-MS based lipidomics. While longer columns packed with smaller particles in theory give higher separation performance compared to shorter columns, the implementation of this technology above commercial limits has been sparse due to difficulties in packing long columns and successfully operating instruments at ultrahigh pressures. In this work, a liquid chromatograph that operates up to 35 kpsi was investigated for the separation and identification of lipid species from human plasma. Capillary columns between 15-50 cm long were packed with 1.7 µm BEH C18 particles and evaluated for their ability to separate lipid isomers and complex lipid extracts from human plasma. Putative lipid class identifications were assigned using accurate mass and relative retention time data of the eluting peaks. Our findings indicate that longer columns packed and operated at 35 kpsi outperform shorter columns packed and run at lower pressures in terms of peak capacity and numbers of features identified. Packing columns with relatively high concentration slurries (200 mg/mL) while sonicating the column resulted in 6-34% increase in peak capacity for 50 cm columns compared to lower slurry concentrations and no sonication. For a given analysis time, 50 cm long columns operated at 35 kpsi provided a 20-95% increase in chromatographic peak capacity compared with 15 cm columns operated at 15 kpsi. Analysis times up to 4 h were evaluated, generating peak capacities up to 410 ± 5 (n = 3, measured at 4σ) and identifying 480 ± 85 lipids (n = 2). Importantly, the results also show a correlation between the peak capacity and the number of lipids identified from a human plasma extract. This correlation indicates that ionization suppression is a limiting factor in obtaining sufficient signal for identification by mass spectrometry. The result also shows that the higher resolution obtained by shallow gradients overcomes possible signal reduction due to broader, more dilute peaks in long gradients for improving detection of lipids in LC-MS. Lastly, longer columns operated at shallow gradients allowed for the best separation of both regional and geometrical isomers. These results demonstrate a system that enables the advantages of using longer columns packed and run at ultrahigh pressure for improving lipid separations and lipidome coverage.

Indexed as

Chromatography, High Pressure LiquidHumansLipidomicsLipidsMass SpectrometrySonicationLipidsCapillary chromatographyLC–MSLipid isomersLipidomicsUHPLC

Identifiers

PMID31607445
PMCPMC6980658

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.