Evidence map›Paper›PMID 31605555›Full record

ArticleMagnetic resonance in medicine2020

Interleaved, undersampled radial multiple-acquisition steady-state free precession for improved left atrial cine imaging.

Jaime S Robb, Chenxi Hu, Dana C Peters

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Joint suppression of cardiac bSSFP cine banding and flow artifacts using twofold phase-cycling and a dual-encoder neural network.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Article
  3. A dual-stage partially interpretable neural network for joint suppression of bSSFP banding and flow artifacts in non-phase-cycled cine imaging.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Jaime S RobbUniversity of Glasgow, Glasgow, UK.
Chenxi HuSchool of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.ORCID 0000-0003-2551-3075
Dana C PetersDepartment of Radiology and Biomedical Imaging, Yale School of Medicine, Yale University, New Haven, Connecticut.

Funding

Yale Clinical and Translational Science Award (U Component)UL1TR001863 · NCATS · YALE UNIVERSITY · PI John H. Krystal, LUCILA OHNO-MACHADO · 2016 to 2026
$102.9M
Development of MR-derived parameters of LV diastolic function: Validation and Comparison to LV and LA fibrosisR01HL144706 · NHLBI · YALE UNIVERSITY · PI PETERS, DANA C · 2019 to 2022
$1.8M
Detection of Atrial Remodeling by MRI: Validation and Emerging SignificanceR01HL122560 · NHLBI · YALE UNIVERSITY · PI PETERS, DANA C · 2015 to 2018
$1.7M
NCATS NIH HHS UL1 TR001863NHLBI NIH HHS R01 HL122560NHLBI NIH HHS R01 HL144706
6 · The paper itself

Abstract

purposeBalanced steady-state free precession (bSSFP) left atrial (LA) cine suffers from off-resonance artifacts, particularly in the pulmonary veins (PVs). Linear combination or multiple-acquisition SSFP (MA-SSFP) effectively removes banding but greatly increases scan time. We hypothesized that MA-SSFP with interleaved radial undersampling, where each phase-cycling is acquired with an interleaved set of radial projections, would improve image quality of LA cine with a small increase of scan time and streak artefacts.

methodsUndersampled radial MA-SSFP with and without interleaving was compared with fully sampled radial bSSFP by means of simulations, phantoms, and in vivo imaging. Ten healthy subjects were imaged on a 3T scanner, with bSSFP and MA-SSFP cine of the left atrium, and B0-mapping. Images were assessed (1 = worst, 5 = best) by 2 independent readers, with respect to 5 qualitative criteria and apparent signal-to-noise ratio.

resultsIn healthy subjects, off-resonance differed from the right inferior PVs to the LA cavity by 163 Hz ± 73 Hz at 3T. Compared with fully sampled radial bSSFP, interleaved radial MA-SSFP significantly improved image quality with respect to off-resonance artifacts (3.8 ± 0.6 versus 2.3 ± 1.0; P = 0.005), PV conspicuity (2.8 ± 1.0 versus 4.3 ± 0.5; P = 0.005), and the number of visualized PVs (1.7 ± 0.4 versus 0.9 ± 0.7; P = 0.008), although with greater streak artifacts (3.4 ± 0.4 versus 4.9 ± 0.2; P = 0.004) and lower measured apparent signal-to-noise ratio (24 ± 9 versus 69 ± 36; P = 0.002). Flow artifacts were similar. Interleaved radial MA-SSFP reduced streaking artifacts and increased apparent signal-to-noise ratio versus noninterleaved radial.

conclusionsInterleaved radial MA-SSFP cine reduces banding artifacts with an acceptable increase of scan time and streak artifacts. The proposed technique improves the LA and PV visualization in bSSFP cine imaging.

Indexed as

ArtifactsImage Interpretation, Computer-AssistedHeart AtriaHumansImage EnhancementMagnetic Resonance ImagingMagnetic Resonance Imaging, CineSignal-To-Noise RatiobSSFPcineleft atriumlinear combination SSFPmultiple acquisition SSFPradial

Identifiers

PMID31605555
PMCPMC6982567

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.