ArticleIEEE transactions on biomedical circuits and systems2019
Vascular Pressure-Flow Measurement Using CB-PDMS Flexible Strain Sensor.
Article in IEEE transactions on biomedical circuits and systems, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 51 citations in OpenAlex.
- Realtime monitoring of thrombus formation in vivo using a self-reporting vascular access graft.Communications medicine · 2024Article
- Flexible and Scalable Dry Conductive Elastomeric Nanocomposites for Surface Stimulation Applications.IEEE transactions on bio-medical engineering · 2023Article
- Beyond Tissue replacement: The Emerging role of smart implants in healthcare.Materials today. Bio · 2023Review
- A Flexible Double Helix Inductive Antenna for RFID Vascular Flow Sensing.IEEE sensors journal · 2023Article
- Low-cost fluorescence microscope with microfluidic device fabrication for optofluidic applications.HardwareX · 2023Article
- Development of an Innovative Soft Piezoresistive Biomaterial Based on the Interconnection of Elastomeric PDMS Networks and Electrically-Conductive PEDOT:PSS Sponges.Journal of functional biomaterials · 2022Article
- Broad-Spectrum Theranostics and Biomedical Application of Functionalized Nanomaterials.Polymers · 2022Review
- Flexible Strain-Sensitive Silicone-CNT Sensor for Human Motion Detection.Bioengineering (Basel, Switzerland) · 2022Article
- Properties and Applications of PDMS for Biomedical Engineering: A Review.Journal of functional biomaterials · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
Regular monitoring of blood flow and pressure in vascular reconstructions or grafts would provide early warning of graft failure and improve salvage procedures. Based on biocompatible materials, we have developed a new type of thin, flexible pulsation sensor (FPS) which is wrapped around a graft to monitor blood pressure and flow. The FPS uses carbon black (CB) nanoparticles dispersed in polydimethylsiloxane (PDMS) as a piezoresistive sensor layer, which was encapsulated within structural PDMS layers and connected to stainless steel interconnect leads. Because the FPS is more flexible than natural arteries, veins, and synthetic vascular grafts, it can be wrapped around target conduits at the time of surgery and remain implanted for long-term monitoring. In this study, we analyze strain transduction from a blood vessel and characterize the electrical and mechanical response of CB-PDMS from 0-50% strain. An optimum concentration of 14% CB-PDMS was used to fabricate 300-μm thick FPS devices with elastic modulus under 500 kPa, strain range of over 50%, and gauge factor greater than 5. Sensors were tested in vitro on vascular grafts with flows of 0-1,100 mL/min. In vitro testing showed linear output to pulsatile flows and pressures. Cyclic testing demonstrated robust operation over hundreds of cardiac cycles, with ±2.6 mmHg variation in pressure readout. CB-PDMS composite material showed excellent potential in biologic strain sensing applications where a flexible sensor with large maximum strain range is needed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials