Evidence map›Paper›PMID 31603827›Full record

ArticleIEEE transactions on biomedical circuits and systems2019

Vascular Pressure-Flow Measurement Using CB-PDMS Flexible Strain Sensor.

Hao Chong, Jiongcheng Lou, Kath M Bogie, Christian A Zorman, Steve J A Majerus

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on biomedical circuits and systems, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 51 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Hao Chong
Jiongcheng Lou
Kath M Bogie
Christian A Zorman
Steve J A Majerus
Louis Stokes Cleveland VA Medical Center · USCase Western Reserve University · US

Funding

Real-Time Monitoring Device for Vascular SignalsIK1RX001968 · VA · LOUIS STOKES CLEVELAND VA MEDICAL CENTER · PI MAJERUS, STEVE · 2016 to 2017
–
RRD VA IK1 RX001968
6 · The paper itself

Abstract

Regular monitoring of blood flow and pressure in vascular reconstructions or grafts would provide early warning of graft failure and improve salvage procedures. Based on biocompatible materials, we have developed a new type of thin, flexible pulsation sensor (FPS) which is wrapped around a graft to monitor blood pressure and flow. The FPS uses carbon black (CB) nanoparticles dispersed in polydimethylsiloxane (PDMS) as a piezoresistive sensor layer, which was encapsulated within structural PDMS layers and connected to stainless steel interconnect leads. Because the FPS is more flexible than natural arteries, veins, and synthetic vascular grafts, it can be wrapped around target conduits at the time of surgery and remain implanted for long-term monitoring. In this study, we analyze strain transduction from a blood vessel and characterize the electrical and mechanical response of CB-PDMS from 0-50% strain. An optimum concentration of 14% CB-PDMS was used to fabricate 300-μm thick FPS devices with elastic modulus under 500 kPa, strain range of over 50%, and gauge factor greater than 5. Sensors were tested in vitro on vascular grafts with flows of 0-1,100 mL/min. In vitro testing showed linear output to pulsatile flows and pressures. Cyclic testing demonstrated robust operation over hundreds of cardiac cycles, with ±2.6 mmHg variation in pressure readout. CB-PDMS composite material showed excellent potential in biologic strain sensing applications where a flexible sensor with large maximum strain range is needed.

Indexed as

Blood Pressure DeterminationBlood Volume DeterminationDimethylpolysiloxanesElectrodes, ImplantedHumansNanoparticlesSootVascular GraftingDimethylpolysiloxanesSoot

Identifiers

PMID31603827
PMCPMC6944770
OpenAlexW2979854938

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked