Evidence map›Paper›PMID 31603567›Full record

ArticleMedical physics2019

Precise measurement of coronary stenosis diameter with CCTA using CT number calibration.

Zhennong Chen, Francisco Contijoch, Andrew Schluchter, Leo Grady, Michiel Schaap, Web Stayman, Jed Pack, Elliot McVeigh

Open access · bronzeAbstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.8field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 6 institutions in 1 country.

Zhennong ChenDepartment of Bioengineering, UC San Diego School of Engineering, La Jolla, CA, 92037-0412, USA.
Francisco ContijochDepartment of Bioengineering, UC San Diego School of Engineering, La Jolla, CA, 92037-0412, USA.
Andrew SchluchterDepartment of Bioengineering, UC San Diego School of Engineering, La Jolla, CA, 92037-0412, USA.
Leo GradyHeartFlow, Inc, Redwood City, CA, 94063, USA.
Michiel SchaapHeartFlow, Inc, Redwood City, CA, 94063, USA.
Web StaymanDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21205, USA.
Jed PackGE Global Research, Niskayuna, NY, USA.
Elliot McVeighDepartment of Bioengineering, UC San Diego School of Engineering, La Jolla, CA, 92037-0412, USA.
HeartFlow (United States) · USUC San Diego Health System · USGE Global Research (United States) · USJohns Hopkins University · USLa Jolla Bioengineering Institute · USUniversity of California, San Diego · US

Funding

Training In Cardiovascular Physiology & PharmacologyT32HL007444 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI Ju Chen, Robert Scott Ross · 1985 to 2026
$11.1M
True 4DCT for Quantifying LV Dyssynchrony and Function for Targeting LV Lead Location in CRTR01HL144678 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI MCVEIGH, ELLIOT R · 2019 to 2022
$3.3M
UCSD PRIDE Faculty Development Program in Cardiovascular SciencesR25HL145817 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI Robert Scott Ross, Joann Trejo · 2019 to 2026
$3.3M
Patient-specific thrombosis risk in atrial fibrillation by 4D CT imaging of atrial kinetics combined with computational fluid dynamicsR01HL160024 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI DEL ALAMO, JUAN CARLOS, KAHN, ANDREW · 2021 to 2024
$2.7M
NHLBI NIH HHS R01 HL144678NHLBI NIH HHS R01 HL160024NHLBI NIH HHS R25 HL145817NHLBI NIH HHS T32 HL007444
6 · The paper itself

Abstract

purposeCoronary x-ray computed tomography angiography (CCTA) continues to develop as a noninvasive method for the assessment of coronary vessel geometry and the identification of physiologically significant lesions. The uncertainty of quantitative lesion diameter measurement due to limited spatial resolution and vessel motion reduces the accuracy of CCTA diagnoses. In this paper, we introduce a new technique called computed tomography (CT)-number-Calibrated Diameter to improve the accuracy of the vessel and stenosis diameter measurements with CCTA.

methodsA calibration phantom containing cylindrical holes (diameters spanning from 0.8 mm through 4.0 mm) capturing the range of diameters found in human coronary vessels was three-dimensional printed. We also printed a human stenosis phantom with 17 tubular channels having the geometry of lesions derived from patient data. We acquired CT scans of the two phantoms with seven different imaging protocols. Calibration curves relating vessel intraluminal maximum voxel value (maximum CT number of a voxel, described in Hounsfield Units, HU) to true diameter, and full-width-at-half maximum (FWHM) to true diameter were constructed for each CCTA protocol. In addition, we acquired scans with a small constant motion (15 mm/s) and used a motion correction reconstruction (Snapshot Freeze) algorithm to correct motion artifacts. We applied our technique to measure the lesion diameter in the 17 lesions in the stenosis phantom and compared the performance of CT-number-Calibrated Diameter to the ground truth diameter and a FWHM estimate.

resultsIn all cases, vessel intraluminal maximum voxel value vs diameter was found to have a simple functional form based on the two-dimensional point spread function yielding a constant maximum voxel value region above a cutoff diameter, and a decreasing maximum voxel value vs decreasing diameter below a cutoff diameter. After normalization, focal spot size and reconstruction kernel were the principal determinants of cutoff diameter and the rate of maximum voxel value reduction vs decreasing diameter. The small constant motion had a significant effect on the CT number calibration; however, the motion-correction algorithm returned the maximum voxel value vs diameter curve to that of stationary vessels. The CT number Calibration technique showed better performance than FWHM estimation of diameter, yielding a high accuracy in the tested range (0.8 mm through 2.5 mm). We found a strong linear correlation between the smallest diameter in each of 17 lesions measured by CT-number-Calibrated Diameter (D

conclusionsComputed tomography-number-Calibrated Diameter is an effective method to enhance the accuracy of the estimate of small vessel diameters and degree of coronary stenosis in CCTA.

Indexed as

Computed Tomography AngiographyImage Processing, Computer-AssistedTomography, X-Ray ComputedArtifactsCalibrationCoronary StenosisMovementPhantoms, Imagingcoronary CT angiographycoronary stenosis quantificationvessel motion

Identifiers

PMID31603567
PMCPMC7700731
OpenAlexW2980231807

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.