Evidence map›Paper›PMID 31600255›Full record

ArticlePloS one2019

Head orientation and electrode placement potentially influence fetal scalp ECG waveform.

Alexandra D J Hulsenboom, Guy J J Warmerdam, Janna Weijers, Paul J Blijham, S Guid Oei, Judith O E H van Laar, Rik Vullings, Tammo Delhaas

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Alexandra D J HulsenboomDepartment of Obstetrics and Gynaecology, Máxima Medical Center, Veldhoven, the Netherlands.
Guy J J WarmerdamFaculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands.
Janna WeijersDepartment of Obstetrics and Gynaecology, Máxima Medical Center, Veldhoven, the Netherlands.
Paul J BlijhamDepartment of Clinical Neurophysiology, Máxima Medical Center, Veldhoven, the Netherlands.
S Guid OeiDepartment of Obstetrics and Gynaecology, Máxima Medical Center, Veldhoven, the Netherlands.
Judith O E H van LaarDepartment of Obstetrics and Gynaecology, Máxima Medical Center, Veldhoven, the Netherlands.
Rik VullingsFaculty of Electrical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands.
Tammo DelhaasDepartment of BioMedical Engineering, Maastricht University Medical Center, Maastricht, the Netherlands.ORCID 0000-0001-6897-9700
Radboud University Nijmegen · NLEindhoven University of Technology · NLMaastricht University · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFetal monitoring based on electrocardiographic (ECG) morphology is obtained from a single unipolar fetal scalp electrode. Ideally, it should be obtained from multiple leads, as ECG waveform depends on alignment between electrode and electrical heart axis. This alignment is unknown in fetuses. Besides, fetuses are surrounded by conductive media, which may influence ECG waveform. We explored the influence of electrode position and head orientation on ECG waveforms of unipolar and bipolar scalp ECGs recorded in air and in conductive medium.

methodsWe recorded ECGs in one adult subject at five different scalp positions in five different head orientations both in dry and immersed conditions. The ratio between T-amplitude and QRS-amplitude (T/QRS ratio) of unipolar and bipolar scalp ECGs was determined and compared between all conditions.

resultsIn the dry condition, we observed in the unipolar leads little to no difference between different electrode positions (maximal T/QRS difference 0.00-0.01) and minor differences between head orientations (0.02-0.03), whereas bipolar leads showed no recognizable ECG signal at all. During the immersed condition, we found variation in the unipolar leads, both between electrode positions (maximal T/QRS difference 0.02-0.05) and between head orientations (0.03-0.06). Bipolar leads showed different ECG signals in contrasting head orientations.

conclusionsBoth unipolar and bipolar scalp lead-derived ECG waveforms are influenced by electrode position and head orientation when the subject is submerged in a conductive medium. Fetal monitoring based on single scalp lead ECG waveform might be suboptimal, as it lacks correction for fetal head orientation and electrode position.

Indexed as

ElectrocardiographyWavelet AnalysisElectrodesFetusHumansImmersionScalp

Identifiers

PMID31600255
PMCPMC6786568
OpenAlexW2979533055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.