ArticleEar and hearing
Interaction Between Electric and Acoustic Stimulation Influences Speech Perception in Ipsilateral EAS Users.
Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- Influence of Electric Frequency-to-Place Mismatches on the Early Speech Recognition Outcomes for Electric-Acoustic Stimulation Users.American journal of audiology · 2023Trial
- Electrode Contacts in the Functional Hearing Region for Pediatric Cochlear Implant Recipients.The Laryngoscope · 2026Article
- Comparing the Effects of Frequency Maps on Sentence Perception Between Simulated Bimodal Hearing and Electric Acoustic Stimulation Hearing.American journal of audiology · 2026Article
- Differences in consonant confusion patterns between bimodal cochlear implant users with greater and less bimodal advantage.Frontiers in psychology · 2025Article
- Speech Recognition and Subjective Hearing Abilities for Electric-Acoustic Stimulation Users With Unilateral Hearing Loss.Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2024Article
- Frequency importance functions in simulated bimodal cochlear-implant users with spectral holes.The Journal of the Acoustical Society of America · 2024Article
- Interactions Between Slopes of Residual Hearing and Frequency Maps in Simulated Bimodal and Electric-Acoustic Stimulation Hearing.Journal of speech, language, and hearing research : JSLHR · 2024Article
- Electro-vibrational stimulation results in improved speech perception in noise for cochlear implant users with bilateral residual hearing.Scientific reports · 2023Article
- Differences in neural encoding of speech in noise between cochlear implant users with and without preserved acoustic hearing.Hearing research · 2023Article
- Cochlear implant spectral bandwidth for optimizing electric and acoustic stimulation (EAS).Hearing research · 2022Article
- A Computational Model of a Single Auditory Nerve Fiber for Electric-Acoustic Stimulation.Journal of the Association for Research in Otolaryngology : JARO · 2022Article
- Effect of Place-Based Versus Default Mapping Procedures on Masked Speech Recognition: Simulations of Cochlear Implant Alone and Electric-Acoustic Stimulation.American journal of audiology · 2022Article
- Forward Electric Stimulation-Induced Interference in Intracochlear Electrocochleography of Acoustic Stimulation in the Cochlea of Guinea Pigs.Frontiers in neuroscience · 2022Article
- Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesThe aim of this study was to determine electric-acoustic masking in cochlear implant users with ipsilateral residual hearing and different electrode insertion depths and to investigate the influence on speech reception. The effects of different fitting strategies-meet, overlap, and a newly developed masking adjusted fitting (UNMASKfit)-on speech reception are compared. If electric-acoustic masking has a detrimental effect on speech reception, the individualized UNMASKfit map might be able to reduce masking and thereby enhance speech reception.
designFifteen experienced MED-EL Flex electrode recipients with ipsilateral residual hearing participated in a crosssover design study using three fitting strategies for 4 weeks each. The following strategies were compared: (1) a meet fitting, dividing the frequency range between electric and acoustic stimulation, (2) an overlap fitting, delivering part of the frequency range both acoustically and electrically, and (3) the UNMASKfit, reducing the electric stimulation according to the individual electric-on-acoustic masking strength. A psychoacoustic masking procedure was used to measure the changes in acoustic thresholds due to the presence of electric maskers. Speech reception was measured in noise with the Oldenburg Matrix Sentence test.
resultsBehavioral thresholds of acoustic probe tones were significantly elevated in the presence of electric maskers. A maximum of masking was observed when the difference in location between the electric and acoustic stimulation was around one octave in place frequency. Speech reception scores and strength of masking showed a dependency on residual hearing, and speech reception was significantly reduced in the overlap fitting strategy. Electric- acoustic stimulation significantly improved speech reception over electric stimulation alone, with a tendency toward a larger benefit with the UNMASKfit map. In addition, masking was significantly inversely correlated to the speech reception performance difference between the overlap and the meet fitting.
conclusions(1) This study confirmed the interaction between ipsilateral electric and acoustic stimulation in a psychoacoustic masking experiment. (2) The overlap fitting yielded poorer speech reception performance in stationary noise especially in subjects with strong masking. (3) The newly developed UNMASKfit strategy yielded similar speech reception thresholds with an enhanced acoustic benefit, while at the same time reducing the electric stimulation. This could be beneficial in the long-term if applied as a standard fitting, as hair cells are exposed to less possibly adverse electric stimulation. In this study, the UNMASKfit allowed the participants a better use of their natural hearing even after 1 month of adaptation. It might be feasible to transfer these results to the clinic, by fitting patients with the UNMASKfit upon their first fitting appointment, so that longer adaptation times can further improve speech reception.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials