ArticleScientific reports2019
Super-Resolution Scanning Transmission X-Ray Imaging Using Single Biconcave Parabolic Refractive Lens Array.
Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 11 citations in OpenAlex.
- X-ray bi-prism interferometry-A design study of proposed novel hardware.Medical physics · 2021Article
- Staircase array of inclined refractive multi-lenses for large field of view pixel super-resolution scanning transmission hard X-ray microscopy.Journal of synchrotron radiation · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
Abstract
A new super resolution imaging technique which potentially enables sub-µm spatial resolution, using a detector of pixels much larger than the spatial resolution, is proposed. The method utilizes sample scanning through a large number of identical X-ray microprobes periodically spaced (the period corresponds to a multiple of the pixel size), which reduces drastically the scanning time. The information about the sample illuminated by the microprobes is stored by large detector pixels. Using these data and sample position information, a super-resolution image reconstruction is performed. With a one-dimensional (1D) high aspect ratio nickel single lens array designed for theoretically expected sub-µm microprobes at 17 keV and fabricated by deep X-ray lithography and electroforming technique, 2 µm X-ray microprobes with a period of 10 µm were achieved. We performed a first experiment at KARA synchrotron facility, and it was demonstrated that the smallest structure of a test pattern with a size of 1.5 µm could be easily resolved by using images generated from a detector having a pixel size of 10.4 µm. This new approach has a great potential for providing a new microscopic imaging modality with a large field of view and short scan time.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.