Trial reportEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2020
How a personalised transportable folding device for seating impacts dysphagia.
Trial report in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02457052 (Impact of a Transportable Customizable and Scalable Sitting Positioning Device on Swallowing Disorders), which is not on this map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Impact of a Transportable Customizable and Scalable Sitting Positioning Device on Swallowing Disorders
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- Behavioural Interventions in People with Oropharyngeal Dysphagia: A Systematic Review and Meta-Analysis of Randomised Clinical Trials.Journal of clinical medicine · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
purposeA personalised transportable folding device for seating (DATP) on a standard seat was developed by an occupational therapist at the Toulouse University Hospital Centre (patent no. WO 2011121249 A1) based on the hypothesis that the use of a seat to assist with better positioning on any chair during meals modifies the sitting posture and has an impact on cervical statics which increases the amplitude of movements of the axial skeleton (larynx and hyoid bone) and benefits swallowing. The aim of this work is to demonstrate that an improvement in sitting posture with the help of the DATP, through Hyoid bone motion, has an impact on the quality of swallowing in a dysphagic population which benefits from the device in comparison to a dysphagic population which does not benefit from the device after 1 month of care. The secondary endpoints concern the evaluation of the impact on other characteristics of swallowing, posture, the acceptability of the device and the quality of life. METHODOLOGY: This is a randomised comparative clinical trial. The blind was not possible for the patients but the examiner who evaluated the outcome criterion was blinded to the group to which the patient belonged. The outcome criterion was the measurement of the hyoid bone movement during swallowing. The other criteria were collected during the videofluoroscopic examination of swallowing and by use of a questionnaire. Fifty-six (56) patients were included: 30 in the group without device (D-) and 26 in the group with the device (D+). All the patients benefited from a training course on seating. Only the D+ patients participated in this course where the use of the device was explained and the device was then kept for use at home for 1 month.
resultsA significant improvement was noted in the postural criteria before and after use, in favour of a better posture for the two groups (p < 0.001) and more hyoid bone motion in the D+ group. The difference was significant in the bivariate analysis for horizontal movement (p = 0.04). After adjustment of potential factors of confusion, we noted a significant mean difference for the three distances in the D+ group in comparison to the D- group, of + 0.33 (95% CI [+ 0.17; + 0.48]) for horizontal movement, + 0.22 (95% CI [+ 0.03; + 0.40]) for vertical movement and + 0.37 (95% CI = [+ 0.20; + 0.53]) for horizontal movement. However, the other parameters, and notably the other swallowing markers were not significantly modified by the use of the device.
conclusionThe personalised transportable folding device for seating developed to reduce dysphagia has an action on hyoid bone motion during swallowing. However, this positive effect on an intermediate outcome criterion of the quality of swallowing was not associated with an improvement in swallowing efficiency in the study population. The diversity of diseases with which the patients in this study were afflicted is a factor to be controlled in future studies with this device.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.