Evidence map›Paper›PMID 31586219›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2020

Performance of the entirely subcutaneous ICD in borderline indications.

Kevin Willy, Florian Reinke, Nils Bögeholz, Julia Köbe, Lars Eckardt, Gerrit Frommeyer

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Outcomes in patients with dual antegrade conduction in the atrioventricular node: insights from a multicentre observational study.Clinical research in cardiology : official journal of the German Cardiac Society · 2020
    Observational
  3. Pulmonary vein isolation treats symptomatic AF in a patient with Lamin A/C mutation: case report and review of the literature.Clinical research in cardiology : official journal of the German Cardiac Society · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Kevin WillyClinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1 Gebäude A1, 48149, Münster, Germany.
Florian ReinkeClinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1 Gebäude A1, 48149, Münster, Germany.
Nils BögeholzClinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1 Gebäude A1, 48149, Münster, Germany.
Julia KöbeClinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1 Gebäude A1, 48149, Münster, Germany.
Lars EckardtClinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1 Gebäude A1, 48149, Münster, Germany.
Gerrit FrommeyerClinic for Cardiology II: Electrophysiology, University Hospital Münster, Albert-Schweitzer-Campus 1 Gebäude A1, 48149, Münster, Germany. gerrit.frommeyer@ukmuenster.de.ORCID http://orcid.org/0000-0002-1431-9886
University Hospital Münster · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe subcutaneous ICD (S-ICD™) is an important advance in device therapy for prevention of sudden cardiac death (SCD). In some patients, decision pro- or contra-ICD implantation is particularly challenging due to inconsistent data on risk of ventricular tachyarrhythmias or sudden cardiac death, rare entities, special medical or family history, or patients' wishes. Whether decision-making in these borderline cases has been facilitated with the new option of a S-ICD™ is unknown. MATERIAL AND

methodsAll patients with an implanted S-ICD™ without a class I or IIa recommendation for primary prophylaxis of sudden cardiac death in the current guidelines (n = 30 patients) in our large-scaled single-centre S-ICD™ registry (n = 249 patients) were included in this study. Baseline characteristics, appropriate and inappropriate shocks, and complications were documented in a mean follow-up of 40 months.

resultsIn all patients S-ICD™ implantation was performed for primary prevention of SCD. Of all 30 patients with an overall mean age of 40.5 ± 15.6 years, 17 were male (57%). The mean left ventricular ejection fraction (LVEF) was 54.5 ± 9.9%. Indication were highly variable and ranged from structural heart disease, nsVT and LV-EF > 35% to patients with polymorphic non-sustained ventricular tachycardia (nsVT) and suspect syncope. During follow-up, six episodes of sustained ventricular tachyarrhythmias and four episodes of ventricular fibrillation (VF) were adequately terminated in three patients (10%). Two of these patients were implanted for polymorphic nsVT and previous syncope without structural heart disease. In three patients, T-wave-oversensing and in one patient also P-wave-oversensing resulted in an inappropriate shock (five in total), two additional episodes of oversensing ended before shock delivery. There were no S-ICD™ system-related infections. In five patients S-ICD™ replacement was performed due to battery depletion (four regular, one premature). In five patients, ablation procedures were performed after implantation (four because of frequent symptomatic ventricular extra beats, one because of atrial flutter). Change to a transvenous system was necessary in two patients due to need for antibradycardia pacing.

conclusionThe use of the S-ICD™ was safe in patients with borderline or unclear indication for ICD implantation in our study. Of note, during a relatively short mean follow-up there were several appropriate therapies, especially for VF in these patients. On the other hand, oversensing also occurred in about 10% of patients, while lead problems were not problematic in this collective. S-ICD™ implantation may be considered as a possible alternative in cases of borderline indications and clinical uncertainty when decision pro-ICD implantation is made. Incidence of arrhythmias was quite high and mostly consisted of VF. Nevertheless, patient education seems even more important as there is a considerable risk for inappropriate therapies as well.

Indexed as

Defibrillators, ImplantableRegistriesAdultArrhythmias, CardiacDeath, Sudden, CardiacElectrocardiographyFemaleFollow-Up StudiesGermanyHumansIncidenceMalePrimary PreventionRetrospective StudiesRisk FactorsStroke VolumeBorderline indicationsS-ICDSudden cardiac death

Identifiers

PMID31586219
OpenAlexW2977319883

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.