Evidence map›Paper›PMID 31586080›Full record

ArticleScientific reports2019

Ex vivo evaluation of an atherosclerotic human coronary artery via histology and high-resolution hard X-ray tomography.

Marzia Buscema, Simone E Hieber, Georg Schulz, Hans Deyhle, Alexander Hipp, Felix Beckmann, Johannes A Lobrinus, Till Saxer, Bert Müller

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Marzia BuscemaBiomaterials Science Center, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
Simone E HieberBiomaterials Science Center, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland. simone.hieber@unibas.ch.
Georg SchulzBiomaterials Science Center, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
Hans DeyhleBiomaterials Science Center, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland.
Alexander HippInstitute of Materials Research, Helmholtz-Zentrum Geesthacht, Geesthacht, Germany.
Felix BeckmannInstitute of Materials Research, Helmholtz-Zentrum Geesthacht, Geesthacht, Germany.
Johannes A LobrinusNeuropathology Unit, University Hospital of Geneva, Geneva, Switzerland.
Till SaxerFaculty of Medicine, University of Geneva, Geneva, Switzerland.
Bert MüllerBiomaterials Science Center, Department of Biomedical Engineering, University of Basel, Allschwil, Switzerland. bert.mueller@unibas.ch.ORCID http://orcid.org/0000-0003-4078-9109
University of Basel · CHHelmholtz-Zentrum Hereon · DEUniversity Hospital of Geneva · CHUniversity of Geneva · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Atherosclerotic arteries exhibit characteristic constrictions and substantial deviations from cylindrical shape. Therefore, determining the artery's cross-section along the centerline is challenging, although high-resolution isotropic three-dimensional data are available. Herein, we apply high-resolution computed tomography in absorption and phase to a plaque-containing human artery post-mortem, through the course of the preparation stages for histology. We identify the impact of paraffin embedding and decalcification on the artery lumen. For automatic extraction of lumen's cross-section along centerline we present a dedicated pipeline. Comparing fixated tissue before and after paraffin embedding gives rise to shape changes with lumen reduction to 50-80%. The histological slicing induces further deformations with respect to tomography. Data acquired after decalcification show debris unintentionally distributed within the vessel preventing the reliable automatic lumen segmentation. Comparing tomography of laboratory- and synchrotron-radiation-based X rays by means of joint histogram analysis leads us to conclude that advanced desktop tomography is capable of quantifying the artery's lumen as an essential input for blood flow simulations. The results indicate that the most reliable lumen quantification is achieved by imaging the non-decalcified specimen fixed in formalin, using phase contrast modality and a dedicated processing pipeline. This study focusses on a methodology to quantitatively evaluate diseased artery segments post-mortem and provides unique structural parameters on the treatment-induced local shrinkage, which will be the basis of future studies on the flow in vessels affected by constrictions.

Indexed as

Imaging, Three-DimensionalTomography, X-Ray ComputedCoronary VesselsHumansParaffin EmbeddingPlaque, Atherosclerotic

Identifiers

PMID31586080
PMCPMC6778097
OpenAlexW2977524400

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.