Evidence map›Paper›PMID 31583537›Full record

ArticleJournal of materials science. Materials in medicine2019

Tantalum-incorporated hydroxyapatite coating on titanium implants: its mechanical and in vitro osteogenic properties.

Rong-Jian Lu, Xing Wang, Hui-Xia He, Ling-Ling E, Ying Li, Gui-Lan Zhang, Chuan-Jie Li, Cheng-Yun Ning, Hong-Chen Liu

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of materials science. Materials in medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 62 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Lanthanides-Substituted Hydroxyapatite for Biomedical Applications.International journal of molecular sciences · 2023
    Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
  15. Article
  16. Review
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Rong-Jian LuDepartment of Stomatology, the Fifth Medical Center, Chinese PLA General Hospital, 100071, Beijing, China.
Xing WangShanxi Medical University School and Hospital of Stomatology, 030001, Taiyuan, China.
Hui-Xia HeDepartment of Stomatology, the First Medical Center, Chinese PLA General Hospital, 100853, Beijing, China.
Ling-Ling EDepartment of Stomatology, the First Medical Center, Chinese PLA General Hospital, 100853, Beijing, China.
Ying LiSchool of Materials Science and Technology, South China University of Technology, 510641, Guangzhou, China.
Gui-Lan ZhangDepartment of Stomatology, the First Medical Center, Chinese PLA General Hospital, 100853, Beijing, China.
Chuan-Jie LiDepartment of Stomatology, the First Medical Center, Chinese PLA General Hospital, 100853, Beijing, China.
Cheng-Yun NingSchool of Materials Science and Technology, South China University of Technology, 510641, Guangzhou, China.
Hong-Chen LiuDepartment of Stomatology, the First Medical Center, Chinese PLA General Hospital, 100853, Beijing, China. liu-hc301@hotmail.com.
Chinese PLA General Hospital · CNSouth China University of Technology · CNShanxi Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe fabrication of bioactive coatings on metallic implants to enhance osseointegration has become a topic of general interest in orthopedics and dentistry. Hydroxyapatite (HA) coating has been shown to induce bone formation and promote bone-implant integration. Unfortunately, poor mechanical performance has hindered this from becoming a favorable coating material. The majority of present studies have focused in incorporating different elements into HA coatings to improve mechanical properties. In recent years, tantalum (Ta) has received increasing attention due to its excellent biocompatibility and corrosion resistance. The aim of on the present study was to investigate the fabrication and biological performance of Ta-incorporated HA coatings.

methodsTa-incorporated HA coatings were fabricated using the plasma spray technique on a titanium substrate, and the surface characteristics and mechanical properties were examined. In addition, the effects of Ta-incorporated HA coatings on the biological behavior of mesenchymal stem cells (BMSCs) were investigated.

resultsTa-incorporated HA coatings with microporous structure had higher roughness and wettability. In addition, the bonding strength of Ta/HA coatings with the substrate was substantially superior to HA coatings. Furthermore, Ta-incorporated HA coatings not only facilitated initial cell adhesion and faster proliferation, but also promoted the osteogenic differentiation of BMSCs.

conclusionThese results indicate that the incorporation of Ta could improve mechanical performance and increase the osteogenic activity of HA coatings. The Ta-incorporated HA coating fabricated by plasma spraying is expected to be a promising bio-coating material for metallic implants.

Indexed as

OsteogenesisAnimalsBiocompatible MaterialsCell AdhesionCell DifferentiationCell ProliferationCells, CulturedCoated Materials, BiocompatibleCorrosionDurapatiteMaterials TestingMesenchymal Stem CellsMetalsOsseointegrationPorosityPowdersBiocompatible MaterialsCoated Materials, BiocompatibleDurapatiteMetalsPowdersTantalumTitanium

Identifiers

PMID31583537
OpenAlexW2978949608

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.