Evidence map›Paper›PMID 31581871›Full record

ArticleThe Journal of international medical research2019

Application of a three-dimensional printed segmental scapula prosthesis in the treatment of scapula tumors.

Linglong Deng, Xing Zhao, Chi Wei, Wenqiang Qu, Li Yu, Shaobo Zhu

Open access · goldAbstract readCase Reports
In one paragraph

Article in The Journal of international medical research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Linglong DengDepartment of Orthopedics, ZhongNan Hospital of Wuhan University, Wuhan University, Wuhan, Hubei, P.R. China.ORCID https://orcid.org/0000-0003-1440-4113
Xing ZhaoDepartment o2f Orthopedics, Taihe Hospital of Shiyan, Shiyan, Hubei, P.R. China.
Chi WeiDepartment of Orthopedics, ZhongNan Hospital of Wuhan University, Wuhan University, Wuhan, Hubei, P.R. China.
Wenqiang QuDepartment of Orthopedics, ZhongNan Hospital of Wuhan University, Wuhan University, Wuhan, Hubei, P.R. China.
Li YuDepartment of Orthopedics, ZhongNan Hospital of Wuhan University, Wuhan University, Wuhan, Hubei, P.R. China.
Shaobo ZhuDepartment of Orthopedics, ZhongNan Hospital of Wuhan University, Wuhan University, Wuhan, Hubei, P.R. China.
Wuhan University · CNTaihe Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

PubMed holds no abstract for this paper.

Indexed as

Printing, Three-DimensionalProstheses and ImplantsBiopsyBone NeoplasmsChondrosarcomaComputer SimulationHumansIntraoperative CareMaleMiddle AgedScapulaShoulderchondrosarcomaimplantprosthesisscapulaThree-dimensional printingtumor

Identifiers

PMID31581871
PMCPMC6862905
OpenAlexW2977282911

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.