Evidence map›Paper›PMID 31579717›Full record

ArticleInnovative surgical sciences2016

Pull-off characteristics of double-shanked compared to single-shanked ligation clips: an animal study.

Martin Schenk, Gottfried Müller, Tim Oliver Greiner, Christine Fahrner, Alfred Königsrainer, Christian Thiel

Open access · goldAbstract read
In one paragraph

Article in Innovative surgical sciences, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 93% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Martin SchenkUniversitätsklinikum Tübingen, Klinik für Allgemeine, Viszeral- und Transplantationschirurgie, Institut für Experimentelle Chirurgie, Tübingen, Germany.
Gottfried MüllerCaritas Krankenhaus, Klinik für Allgemeine, Visceral- und Gefäßchirurgie, Bad Mergentheim, Germany.
Tim Oliver GreinerUniversitätsklinikum Tübingen, Klinik für Allgemeine, Viszeral- und Transplantationschirurgie, Institut für Experimentelle Chirurgie, Tübingen, Germany.
Christine FahrnerUniversitätsklinikum Tübingen, Klinik für Allgemeine, Viszeral- und Transplantationschirurgie, Institut für Experimentelle Chirurgie, Tübingen, Germany.
Alfred KönigsrainerUniversitätsklinikum Tübingen, Klinik für Allgemeine, Viszeral- und Transplantationschirurgie, Institut für Experimentelle Chirurgie, Tübingen, Germany.
Christian ThielUniversitätsklinikum Tübingen, Klinik für Allgemeine, Viszeral- und Transplantationschirurgie, Institut für Experimentelle Chirurgie, Tübingen, Germany.
Universitätsklinikum Tübingen · DECaritas-Krankenhaus Bad Mergentheim · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe use of surgical ligation clips is considered as the gold standard for the closure of vessels, particularly in laparoscopic surgery. The safety of clips is mainly achieved by the deep indentation of the metal bar with a high retention force. A novel double-shanked (DS) titanium clip was compared to two single-shanked clips with respect to axial and radial pull-off forces.

methodsIn a porcine model (8 animals, 51±1 kg), arteries were prepared immediately after euthanisation, assigned to either a medium (2-4 mm; n=120) or a medium-large (3.5-7 mm; n=120) clip size group, and clipped with the appropriate clip size. After dissection, axial and radial pull-off forces were measured.

resultsThe axial pull-off force of the DS-Clip was higher than one single-shanked clip and comparable to the other single-shanked clip, and overall was linearly correlated to the cross-sectional area of the clip. The radial pull-off force of the DS-Clip was significantly higher than both single-shanked clips and, for the single-shanked clips, was correlated to the total clip thickness. The variation of radial pull-off force was lower for the DS-Clip due to a defined catch in the clip applier.

conclusionsThe radial pull-off force was lower than the axial pull-off force in total and therefore appears to be the critical point of dislocation. Due to the higher total holding mass, the DS-Clip provided a clear advantage in this regard and might therefore decrease the dislocation rate. The catch in the applier increases the reproducibility in clip placement.

Indexed as

double-shankedpull-off forcesurgical ligation clipstitanium

Identifiers

PMID31579717
PMCPMC6753983
OpenAlexW2462931124

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.