Evidence map›Paper›PMID 31578595›Full record

ArticleJournal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie2019

Effect of in vitro aging by water immersion and thermocycling on the mechanical properties of PETG aligner material.

Benjamin A Ihssen, Jan H Willmann, Amr Nimer, Dieter Drescher

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
35citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

35 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Effect of thermomechanical aging on force system of orthodontic aligners made of different thermoformed materials : An in vitro study.Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2025
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Benjamin A IhssenDepartment of Orthodontics, University of Duesseldorf, Moorenstraße 5, 40225, Duesseldorf, Germany.ORCID http://orcid.org/0000-0002-4995-7386
Jan H WillmannDepartment of Orthodontics, University of Duesseldorf, Moorenstraße 5, 40225, Duesseldorf, Germany. Jan.willmann@med.uni-duesseldorf.de.ORCID http://orcid.org/0000-0002-3882-246X
Amr NimerDivision of Surgery, Imperial College London, South Kensington, SW7 2AZ, London, UK.ORCID http://orcid.org/0000-0001-6365-4579
Dieter DrescherDepartment of Orthodontics, University of Duesseldorf, Moorenstraße 5, 40225, Duesseldorf, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe mechanical properties of orthodontic aligners made from thermoplastic polymers decrease over time in the intraoral milieu. However, there is a lack of information on this topic in the literature. Thus, the elastic properties of polyethylene terephthalate glycol (PETG) aligner films were investigated in vitro under extreme temperature changes simulated by thermocycling, environmental temperature and water absorption. MATERIALS AND

methodsA total of 60 specimens made from PETG aligner films (CA Clear Aligner, Scheu Dental, Iserlohn, Germany) were divided into three groups (immersed in distilled water, subjected to accelerated ageing by thermocycling, control). These groups were again divided and tensile testing was performed for all groups at 22 and at 37 °C. Young's modulus (E), 0.2% offset yield strength (R

resultsAll treated specimens showed water absorption, whereby specimens that were thermocycled absorbed 48% more water than the immersed ones. Young's modulus and UTS were significantly lower for all three groups at 37 °C compared to the corresponding groups tested at 22 °C. Thermocycled and immersed groups showed a significantly lower Young's modulus compared to the control group tested at the same temperature. The mean R

conclusionsThe results of this study add to the understanding of the clinically well-known degradation of orthodontic aligners during wear time. Extreme alternating temperatures along with warming up to intraoral temperature and water absorption can reduce the material's Young's modulus and may therefore promote a decrease of resulting orthodontic forces.

Indexed as

AgingWaterElastic ModulusGermanyMaterials TestingPolyethylene GlycolsPolyethylene TerephthalatesTensile StrengthPolyethylene Glycolspolyethylene terephthalate glycolPolyethylene TerephthalatesWaterArtificial ageingElastic modulusMechanical phenomenaOrthodontic tooth movementTensile strength

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.