Article in Journal of neural engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed.
- Functional Somatotopy of Lumbar Dorsal Rootlets and its Role in Selective Recruitment via Lateral Spinal Cord Stimulation.bioRxiv : the preprint server for biology · 2026Article
- Tonic Stimulation of Dorsal Root Ganglion Results in Progressive Decline in Recruitment of Aα/β-Fibers in Rats.Neuromodulation : journal of the International Neuromodulation Society · 2024Article
- The effects of neuron morphology and spatial distribution on the selectivity of dorsal root ganglion stimulation.Journal of neural engineering · 2024Article
- Clinical Applications and Future Translation of Somatosensory Neuroprostheses.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2024Review
- Computational modeling of dorsal root ganglion stimulation using an Injectrode.Journal of neural engineering · 2024Article
- Neuromorphic hardware for somatosensory neuroprostheses.Nature communications · 2024Review
- High-density spinal cord stimulation selectively activates lower urinary tract nerves.Journal of neural engineering · 2022Article
- Dorsal Root Ganglion Stimulation for Chronic Pain: Hypothesized Mechanisms of Action.The journal of pain · 2022Review
- Stimulation of the dorsal root ganglion using an InjectrodeJournal of neural engineering · 2021Article
- Selective stimulation of the ferret abdominal vagus nerve with multi-contact nerve cuff electrodes.Scientific reports · 2021Article
- Recruitment of Primary Afferents by Dorsal Root Ganglion Stimulation using the Injectrode.International IEEE/EMBS Conference on Neural Engineering : [proceedings]. International IEEE EMBS Conference on Neural Engineering · 2021Article
- High-density neural recordings from feline sacral dorsal root ganglia with thin-film array.Journal of neural engineering · 2021Article
- Host tissue response to floating microelectrode arrays chronically implanted in the feline spinal nerve.Journal of neural engineering · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
objectiveWe have shown previously that microstimulation of the lumbar dorsal root ganglia (L5-L7 DRG) using penetrating microelectrodes, selectively recruits distal branches of the sciatic and femoral nerves in an acute preparation. However, a variety of challenges limit the clinical translatability of DRG microstimulation via penetrating electrodes. For clinical translation of a DRG somatosensory neural interface, electrodes placed on the epineural surface of the DRG may be a viable path forward. The goal of this study was to evaluate the recruitment properties of epineural electrodes and compare their performance with that of penetrating electrodes. Here, we compare the number of selectively recruited distal nerve branches and the threshold stimulus intensities between penetrating and epineural electrode arrays. APPROACH: Antidromically propagating action potentials were recorded from multiple distal branches of the femoral and sciatic nerves in response to epineural stimulation on 11 ganglia in four cats to quantify the selectivity of DRG stimulation. Compound action potentials (CAPs) were recorded using nerve cuff electrodes implanted around up to nine distal branches of the femoral and sciatic nerve trunks. We also tested stimulation selectivity with penetrating microelectrode arrays implanted into ten ganglia in four cats. A binary search was carried out to identify the minimum stimulus intensity that evoked a response at any of the distal cuffs, as well as whether the threshold response selectively occurred in only a single distal nerve branch. MAIN
resultsStimulation evoked activity in just a single peripheral nerve through 67% of epineural electrodes (35/52) and through 79% of the penetrating microelectrodes (240/308). The recruitment threshold (median = 9.67 nC/phase) and dynamic range of epineural stimulation (median = 1.01 nC/phase) were significantly higher than penetrating stimulation (0.90 nC/phase and 0.36 nC/phase, respectively). However, the pattern of peripheral nerves recruited for each DRG were similar for stimulation through epineural and penetrating electrodes. SIGNIFICANCE: Despite higher recruitment thresholds, epineural stimulation provides comparable selectivity and superior dynamic range to penetrating electrodes. These results suggest that it may be possible to achieve a highly selective neural interface with the DRG without penetrating the epineurium.